Certain products may not be available in your region
Key Applications
Key Features
...
...
|
|
|
Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.
Schedule AccessOptional Parts List | |||
Part Number | Qty | Description | |
3808 HBA Card | AOC-S3808L-L8IT | 1 | Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
3816 HBA Card | AOC-S3816L-L16IT | 1 | Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA |
CBL-SAST-1265F-100 | 1 | Slimline x8 (STR) to Slimline x4 (STR) 64CM | |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
3908 RAID Card | AOC-S3908L-H8IR-16DD | 1 | Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60 |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
3908/3916 CacheVault | BTR-CVPM05 | 1 | CacheVault for Broadcom 3908/3916 (requires a mount) |
3916 RAID Card | AOC-S3916L-H16IR-32DD | 1 | Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60 |
CBL-SAST-1265F-100 | 1 | Slimline x8 (STR) to Slimline x4 (STR) 64CM | |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
AIOM Network Card(s) | AOC-AG-i4SM | - | OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4 |
AOC-ATGC-i2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2 | |
AOC-AG-i4M | - | OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4 | |
AOC-AG-i2M | - | OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2 | |
AOC-A100G-b2CM | - | OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508 | |
AOC-A25G-b2SM | - | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Broadcom® BCM57414 | |
AOC-A25G-i2SM | - | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2 | |
AOC-A25G-i4SM | - | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 | |
AOC-A25G-m2SM | - | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX | |
AOC-AH25G-m2S2TM | - | OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2 | |
AOC-ATG-b2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416 | |
AOC-ATG-i2SM | - | OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2 | |
AOC-ATG-i2T2SM | - | OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4 | |
AOC-ATG-i2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2 | |
AOC-ATG-i4SM | - | OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1 | |
Cable Management Arm | MCP-120-82601-0N | 1 | Cable Arm Adapter |
MCP-290-00073-0N | 1 | Supermicro Cable Management Arm for 2U, 3U and 4U chassis | |
CacheVault Mount | MCP-240-00203-0N | 1 | CacheVault mounting bracket for PCIe slot |
MCP-240-21747-0N | 1 | CacheVault mounting card for AIOM slot | |
MCP-240-00127-0N | 1 | CacheVault mounting tray for 2.5" drive bay | |
GPU Power Cable | CBL-PWEX-1040 | 2 | PWYCB GPU 2x4M/CPU to two (2x3F+2x1F)/PCIe P4.2 5CM |
CBL-PWEX-1361RF-10 | 1 | 12VHPWR 2x6+4S to ATX 2X4M P4.2 10cm | |
GPU Support (FL) | SNK-P0087V | 2 | 1U Passive CPU VC HS for X13 Intel Eagle Stream Platform |
MCP-310-82621-0N | 1 | Plastic air shroud X13DDW for SCLA26-AW (GPU) | |
GPU Support (LP) | MCP-310-82614-0B | 1 | Mylar air block set X12DDW for SCLA26-AW |
License | SFT-SDDC-SINGLE | 1 | Supermicro Data Center Monitor License |
SFT-DCMS-SINGLE •![]() |
1 | Supermicro System Managment Software License | |
M.2 Tray | AOC-SLG4-2H8M2 | - | Standard LP PCIe x8 supporting 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0, 1 |
NC-SI Cable | CBL-PWEX-1099-34 | 1 | FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM |
NVMe Cable | CBL-KIT-621C-TN12R-12 | 1 | Enables 12 NVMe drive bays. Kit includes: 4x CBL-MCIO-1235M5FY (bay #2-5, #8-11) 2x CBL-MCIO-1255M5FH (bay # 0-1, #6-7) |
Power Supply | PWS-1K11P-1R | 2 | DC 48V Input 1010W Power Supply |
PWS-1K23A-1R | 2 | (Default) AC-DC 1200W Titanium Level Power Supply | |
PWS-1K68A-1R | 2 | AC-DC 1600W Titanium Level Power Supply | |
Rear NVMe Drive Kit | CBL-MCIO-1235M5FY •![]() |
1 | MCIO x8 (STR) to 2x MCIO x4 (STR) 35CM |
CBL-PWEX-1034Z-30 | 1 | 2 ATX 1x4 P4.2 to MicroHi 2x(4+2) 30cm 16AWG | |
MCP-220-82623-0N | 1 | Rear Window Module for 2x 2.5" NVMe Drives PCIE Gen 5 | |
Rear SATA Drive Kit | MCP-220-82616-0N | 1 | Rear Window Module for 2x 2.5" SATA/SAS Drives |
SATA Cable | CBL-KIT-SATA-CDC-1 | 1 | Enables 12 SATA drive bays. Kit includes: 1x CBL-SAST-1274LP-100 (bay #0-7) 1x CBL-SAST-1285LP-100 (bay #8-11) |
TPM | AOM-TPM-9670V | 1 | SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor |
AOM-TPM-9670V-S-FIPS | 1 | SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor | |
AOM-TPM-9672V | 1 | SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor | |
AOM-TPM-9672V-FIPS | 1 | SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor | |
VROC HW Key | AOC-VROCPREMOD | 1 | Intel VROC Premium RAID 0, 1, 5, 10 |
AOC-VROCSTNMOD | 1 | Intel VROC Standard RAID 0, 1, 10 |
Part Number | AOC-S3808L-L8IT | CBL-SAST-1276F-100 |
Qty | 1 | 1 |
Description | Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | AOC-S3816L-L16IT | CBL-SAST-1265F-100 | CBL-SAST-1276F-100 |
Qty | 1 | 1 | 1 |
Description | Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA | Slimline x8 (STR) to Slimline x4 (STR) 64CM | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | AOC-S3908L-H8IR-16DD | CBL-SAST-1276F-100 |
Qty | 1 | 1 |
Description | Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | BTR-CVPM05 |
Qty | 1 |
Description | CacheVault for Broadcom 3908/3916 (requires a mount) |
Part Number | AOC-S3916L-H16IR-32DD | CBL-SAST-1265F-100 | CBL-SAST-1276F-100 |
Qty | 1 | 1 | 1 |
Description | Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60 | Slimline x8 (STR) to Slimline x4 (STR) 64CM | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | AOC-AG-i4SM | AOC-ATGC-i2TM | AOC-AG-i4M | AOC-AG-i2M | AOC-A100G-b2CM | AOC-A25G-b2SM | AOC-A25G-i2SM | AOC-A25G-i4SM | AOC-A25G-m2SM | AOC-AH25G-m2S2TM | AOC-ATG-b2TM | AOC-ATG-i2SM | AOC-ATG-i2T2SM | AOC-ATG-i2TM | AOC-ATG-i4SM |
Qty | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Description | OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4 | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2 | OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4 | OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2 | OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508 | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Broadcom® BCM57414 | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2 | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX | OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2 | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416 | OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2 | OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4 | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2 | OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1 |
Part Number | MCP-120-82601-0N | MCP-290-00073-0N |
Qty | 1 | 1 |
Description | Cable Arm Adapter | Supermicro Cable Management Arm for 2U, 3U and 4U chassis |
Part Number | MCP-240-00203-0N | MCP-240-21747-0N | MCP-240-00127-0N |
Qty | 1 | 1 | 1 |
Description | CacheVault mounting bracket for PCIe slot | CacheVault mounting card for AIOM slot | CacheVault mounting tray for 2.5" drive bay |
Part Number | CBL-PWEX-1040 | CBL-PWEX-1361RF-10 |
Qty | 2 | 1 |
Description | PWYCB GPU 2x4M/CPU to two (2x3F+2x1F)/PCIe P4.2 5CM | 12VHPWR 2x6+4S to ATX 2X4M P4.2 10cm |
Part Number | SNK-P0087V | MCP-310-82621-0N |
Qty | 2 | 1 |
Description | 1U Passive CPU VC HS for X13 Intel Eagle Stream Platform | Plastic air shroud X13DDW for SCLA26-AW (GPU) |
Part Number | MCP-310-82614-0B |
Qty | 1 |
Description | Mylar air block set X12DDW for SCLA26-AW |
Part Number | SFT-SDDC-SINGLE | SFT-DCMS-SINGLE •![]() |
Qty | 1 | 1 |
Description | Supermicro Data Center Monitor License | Supermicro System Managment Software License |
Part Number | AOC-SLG4-2H8M2 |
Qty | - |
Description | Standard LP PCIe x8 supporting 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0, 1 |
Part Number | CBL-PWEX-1099-34 |
Qty | 1 |
Description | FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM |
Part Number | CBL-KIT-621C-TN12R-12 |
Qty | 1 |
Description | Enables 12 NVMe drive bays. Kit includes: ,4x CBL-MCIO-1235M5FY (bay #2-5, #8-11) ,2x CBL-MCIO-1255M5FH (bay # 0-1, #6-7) |
Part Number | PWS-1K11P-1R | PWS-1K23A-1R | PWS-1K68A-1R |
Qty | 2 | 2 | 2 |
Description | DC 48V Input 1010W Power Supply | (Default) AC-DC 1200W Titanium Level Power Supply | AC-DC 1600W Titanium Level Power Supply |
Part Number | MCP-220-82616-0N |
Qty | 1 |
Description | Rear Window Module for 2x 2.5" SATA/SAS Drives |
Part Number | CBL-KIT-SATA-CDC-1 |
Qty | 1 |
Description | Enables 12 SATA drive bays. Kit includes: ,1x CBL-SAST-1274LP-100 (bay #0-7) ,1x CBL-SAST-1285LP-100 (bay #8-11) |
Part Number | AOM-TPM-9670V | AOM-TPM-9670V-S-FIPS | AOM-TPM-9672V | AOM-TPM-9672V-FIPS |
Qty | 1 | 1 | 1 | 1 |
Description | SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor | SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor | SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor | SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor |
Part Number | AOC-VROCPREMOD | AOC-VROCSTNMOD |
Qty | 1 | 1 |
Description | Intel VROC Premium RAID 0, 1, 5, 10 | Intel VROC Standard RAID 0, 1, 10 |