SuperServer SYS-241E-TNRTTP

DatasheetShare IconShare

2U 4-socket system with 64 DIMMs and 24 NVMe/SAS/SATA drive bays

Integrated Board: X13QEH+
Learn more

Key Applications

  • Artificial Intelligence (AI)
  • Business Intelligence
  • ERP, CRM
  • Scientific Virtualization
  • In-Memory Database
  • HCI
  • SAP HANA

Key Features

  1. Quad Socket E (LGA-4677) 4th Generation Intel® Xeon® Scalable processors
  2. 64 DIMM Slots; Up to 8TB DDR5-4800MHz ECC RDIMM/RDIMM-3DS
  3. Optional PCIe configurations up to 8 PCIe slots with support for two double-width GPU/Accerlator cards
  4. Flexible networking options with 2 AIOM networking slot (OCP NIC 3.0 compatible)
  5. 24x 2.5" Hot-swap NVMe/SAS3/SATA3 Hybrid Drive bays (Default with 24 SAS3/SATA3 drive bays); 2x internal M.2 NVMe/SATA; Optional RAID support via storage add-on card
    • 6 heavy duty fans w/ optimal fan speed control
    • Liquid cooling solution is available-please contact your Supermicro sales rep for more info.
...
...
SYS-241E-TNRTTP
Specifications Free Remote Testing Parts List
Specifications
Product SKUs
SuperServer SYS-241E-TNRTTP
Motherboard
Super X13QEH+
Processor
CPU
Note
  • Supports 165W - 250W TDP CPUs (Air Cooled)
  • Supports up to 350W TDP CPUs (Liquid Cooled)​
GPU
Max GPU Count
  • Up to 2 double-width GPUs
Supported GPU
CPU-GPU Interconnect
  • PCIe 5.0 x16 CPU-to-GPU Interconnect
GPU-GPU Interconnect
  • PCIe
System Memory
Memory
Memory Voltage
  • 1.1V
On-Board Devices
Chipset
  • Intel® C741
Network Connectivity
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated BMC LAN port
USB
  • 2 USB 3.0 ports(rear)
  • 2 USB 2.0 ports(front)
Video
  • 1 VGA port
  • 1 DisplayPort port
Serial
  • 1 COM port(Rear)
System BIOS
BIOS Type
  • AMI 32MB SPI Flash EEPROM
Management
Software
Power configurations
  • Power-on mode for AC power recovery
  • ACPI Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • Supply Chain Security: Remote Attestation
  • Runtime BMC Protections
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
  • 4+1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-218HTS-R3K2AWP
Dimensions and Weight
Height
  • 3.5" (87.9 mm)
Width
  • 17.3" (438.4 mm)
Depth
  • 33.4" (849.3 mm)
Package
  • 9.75" (H) x 26.5" (W) x 43.5" (D)
Weight
  • Gross Weight: 71.5 lbs (32.43 kg)
  • Net Weight: 45.5 lbs (20.64 kg)
Available Color
  • Black
Front Panel
LED
  • HDD activity
  • Network activity
  • Power status
  • System information (overheat/UID) 
Buttons
  • Power On/Off
  • UID
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 3 PCIe 5.0 x8 FHHL slots
    • 3 PCIe 5.0 x16 FHHL slots
    • 1 PCIe 5.0 x8 AIOM slot (OCP 3.0 compatible)
    • 1 PCIe 5.0 x16 AIOM slot (OCP 3.0 compatible)
  • Option A
    • 2 PCIe 5.0 x16 FHFL double-width slots
    • 2 PCIe 5.0 x16 FHHL slots
    • 1 PCIe 5.0 x8 AIOM slot (OCP 3.0 compatible)
    • 1 PCIe 5.0 x16 AIOM slot (OCP 3.0 compatible)
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 8 bays
    • 8 front hot-swap 2.5" SATA drive bays
  • Option A: Total 24 bays
    • 24 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays
  • (*NVMe/SAS/SATA support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View NVMe Options
  • View Drive Options
M.2
System Cooling
Fans
  • 6 Heavy duty counter-rotating 6cm Fan(s)
  • 4 Direct to Chip (D2C) Cold Plate Fan(s) (optional)
Air Shroud
  • 4 Air Shrouds
Liquid Cooling
  • Direct to Chip (D2C) Cold Plate (optional)
Power Supply
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 10°C to 35°C (50°F to 95°F)
  • Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 90% (Non-Condensing)
  • Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
Free Remote Testing

Get free access to Supermicro’s top-end data center servers right from your browser with JumpStart

Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.

Schedule Access
Resources & Downloads
Parts List
Optional Parts List
Part Number Qty Description
CPU Carrier (Require 4pcs of one PN only) SKT-1424L-001B-LTS 4 Intel SPR 64xxH Socket E E1B carrier LGA 4677 W/SHIM SPR MCC, DG1.0 ,RoHS (Brand LOTES)
SKT-1424L-001B-FXC 4 Intel SPR 64xxH Socket E E1B carrier LGA 4677 W/SHIM SPR MCC, DG1.0, RoHS (Brand FOXCONN)
SKT-1333L-0001-LTS 4 Intel SPR 84xxH Socket E LGA4677, E1A XCC carrier, DG 1.0, NO SHIM, (Brand LOTES)
SKT-1333L-0000-FXC 4 Intel SPR 84xxH Socket E LGA4677, E1A XCC carrier, DG 1.0, RoHS (Brand FOXCONN)
GPU DW FL Support Kit MCP-310-21820-0B 2 1U Evac CPU Air Shroud
MCP-240-21828-0N 1 GPU card bracket set for DW full length GPU (Supports 2x DW GPUs)
SNK-P2087PV-2 1 1U Right EVAC CPU Heat Sink
SNK-P2087PV-1 1 1U Left EVAC CPU Heat Sink
GPU Power Cable(s) CBL-PWEX-1040 1/GPU 8-pin CPU to 8-pin PCIe power connector (Requires 1x CBL-PWEX-1148-20)
CBL-PWEX-1148-20 1/GPU 8-pin CPU power cable (Example A6000, A100, A40 and etc.)
CBL-PWEX-0962Y-20 1/GPU 16-pin power cable (Example H100)
Intel 6434H High Frequency Support SNK-P2088P 2 2U Passive EVAC CPU Heat Sink for X13 241H/E Series Servers
NVMe Intel VROC Controller AOC-VROCPREMOD 1 Intel VROC Premium, RAID 0, 1, 5, 10
AOC-VROCSTNMOD 1 Intel VROC HW key (RSTe) standard upgrade module
NVMe Support Kit CBL-MCIO-1210M5 1 ~ 12 MCIO x8 (STR to STR),10CM,85OHM,RoHS (1 cable supports 2 NVMe U.2 Drives)
MCP-220-00196-0B 1 ~ 24 Metallic black gen-3 hot-swap 2.5" NVMe tool-less tray
Power Supply PWS-1K62A-1R 1 ~ 4 AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH
RAID Controller 01-08pcs SATA3/SAS CBL-SAST-1281-100 1 Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
AOC-S3908L-H8IR-16DD 1 8 int 12Gb/s ports, x8 Gen4, ROC - LP
RAID Controller 09-16pcs SATA3/SAS AOC-S3916L-H16IR-32DD 1 16 int 12Gb/s ports, x8 Gen4, ROC - LP
CBL-SAST-1281-100 2 Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
RAID Controller 17-24pcs SATA3/SAS CBL-SAST-1281-100 3 Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
AOC-S3916L-H16IR-32DD 1 16 int 12Gb/s ports, x8 Gen4, ROC - LP
AOC-S3908L-H8IR-16DD 1 8 int 12Gb/s ports, x8 Gen4, ROC - LP
RAID Controller CacheVault(s) MCP-240-00203-0N 1 BTR-CVPM05 Supercap mounting bracket for PCIe location (Support up to 2 BTR)
BTR-CV3916-U1 1 ~ 2 CacheVault Supercap with chassis sidewall mounting kit
BTR-CVPM05 1 ~ 2 CacheVault for Broadcom RAID Controller (Ex. S3908/S3916)
Rail w/ Cable Arm Support Kit MCP-290-00127-0N 1 39" rail set, quick/quick, 17.2"W, for 2U Gen2 cable arm
MCP-290-00128-0N 1 Gen2 cable arm for Ultra 2U
TPM Security Module AOM-TPM-9672V 1 TPM 2.0 with 10 pins SPI,RoHS (Vertical)
AOM-TPM-9672V-FIPS 1 TPM 2.0 with 10 pins SPI support FIPS 140,RoHS (Vertical)
AOM-TPM-9670V 1 SPI TPM 2.0 using SLB9670 (Vertical)
Optional Parts List
CPU Carrier (Require 4pcs of one PN only)
Part NumberSKT-1424L-001B-LTSSKT-1424L-001B-FXCSKT-1333L-0001-LTSSKT-1333L-0000-FXC
Qty4444
DescriptionIntel SPR 64xxH Socket E E1B carrier LGA 4677 W/SHIM SPR MCC, DG1.0 ,RoHS (Brand LOTES)Intel SPR 64xxH Socket E E1B carrier LGA 4677 W/SHIM SPR MCC, DG1.0, RoHS (Brand FOXCONN)Intel SPR 84xxH Socket E LGA4677, E1A XCC carrier, DG 1.0, NO SHIM, (Brand LOTES)Intel SPR 84xxH Socket E LGA4677, E1A XCC carrier, DG 1.0, RoHS (Brand FOXCONN)
GPU DW FL Support Kit
Part NumberMCP-310-21820-0BMCP-240-21828-0NSNK-P2087PV-2SNK-P2087PV-1
Qty2111
Description1U Evac CPU Air ShroudGPU card bracket set for DW full length GPU (Supports 2x DW GPUs)1U Right EVAC CPU Heat Sink1U Left EVAC CPU Heat Sink
GPU Power Cable(s)
Part NumberCBL-PWEX-1040 CBL-PWEX-1148-20 CBL-PWEX-0962Y-20
Qty1/GPU1/GPU1/GPU
Description8-pin CPU to 8-pin PCIe power connector (Requires 1x CBL-PWEX-1148-20)8-pin CPU power cable (Example A6000, A100, A40 and etc.)16-pin power cable (Example H100)
Intel 6434H High Frequency Support
Part NumberSNK-P2088P
Qty2
Description2U Passive EVAC CPU Heat Sink for X13 241H/E Series Servers
NVMe Intel VROC Controller
Part NumberAOC-VROCPREMODAOC-VROCSTNMOD
Qty11
DescriptionIntel VROC Premium, RAID 0, 1, 5, 10Intel VROC HW key (RSTe) standard upgrade module
NVMe Support Kit
Part NumberCBL-MCIO-1210M5MCP-220-00196-0B
Qty1 ~ 121 ~ 24
DescriptionMCIO x8 (STR to STR),10CM,85OHM,RoHS (1 cable supports 2 NVMe U.2 Drives)Metallic black gen-3 hot-swap 2.5" NVMe tool-less tray
Power Supply
Part NumberPWS-1K62A-1R
Qty1 ~ 4
DescriptionAC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH
RAID Controller 01-08pcs SATA3/SAS
Part NumberCBL-SAST-1281-100AOC-S3908L-H8IR-16DD
Qty11
DescriptionSlimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM8 int 12Gb/s ports, x8 Gen4, ROC - LP
RAID Controller 09-16pcs SATA3/SAS
Part NumberAOC-S3916L-H16IR-32DDCBL-SAST-1281-100
Qty12
Description16 int 12Gb/s ports, x8 Gen4, ROC - LPSlimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM
RAID Controller 17-24pcs SATA3/SAS
Part NumberCBL-SAST-1281-100AOC-S3916L-H16IR-32DDAOC-S3908L-H8IR-16DD
Qty311
DescriptionSlimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM16 int 12Gb/s ports, x8 Gen4, ROC - LP8 int 12Gb/s ports, x8 Gen4, ROC - LP
RAID Controller CacheVault(s)
Part NumberMCP-240-00203-0N BTR-CV3916-U1BTR-CVPM05
Qty11 ~ 21 ~ 2
DescriptionBTR-CVPM05 Supercap mounting bracket for PCIe location (Support up to 2 BTR)CacheVault Supercap with chassis sidewall mounting kitCacheVault for Broadcom RAID Controller (Ex. S3908/S3916)
Rail w/ Cable Arm Support Kit
Part NumberMCP-290-00127-0NMCP-290-00128-0N
Qty11
Description39" rail set, quick/quick, 17.2"W, for 2U Gen2 cable armGen2 cable arm for Ultra 2U
TPM Security Module
Part NumberAOM-TPM-9672VAOM-TPM-9672V-FIPSAOM-TPM-9670V
Qty111
DescriptionTPM 2.0 with 10 pins SPI,RoHS (Vertical)TPM 2.0 with 10 pins SPI support FIPS 140,RoHS (Vertical)SPI TPM 2.0 using SLB9670 (Vertical)

MP SuperServer SYS-241E-TNRTTP

Certain products may not be available in your region