Key Applications
Key FeaturesFour hot-pluggable systems (nodes) in a 2U form factor. Each node supports the following:
...
...
|
|
|
Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.
Schedule AccessStandard Parts (Parts Included) | |||
Part Number | Qty | Description | |
Motherboard / Chassis |
MBD-H12DST-B CSE-217BHQ+-R2K22BP2 |
4 1 |
Super H12DST-B Motherboard 2U Chassis |
Backplane | BPN-ADP-6SATA3-1UB | 4 | Support 6 SATA HDD adaptor card for Big Twin |
BPN-SAS3-217BHQ | 1 | 2U 4-Node 24-Port 12G Backplane Supports 6x2.5" SAS3/SATA3 | |
Drive Tray(s) | MCP-220-00141-0B-BULK | 24 | Black Gen3 hot-swap 2.5 inch HDD tray with lock improved EMI |
Manual | MNL-2211-QRG | 1 | AS -2124BT-HTR/-HNR/-HNTR/-HNC0R Quick Reference Guide |
Riser Card | RSC-P-6-X2 | 4 | 1U LHS TwinPro riser card with one PCIe 4.0 x16 slot,HF,RoH |
RSC-PR-6-X2 | 4 | 1U RHS TwinPro Riser card with one PCIe 4.0 x16 slot,HF,RoH | |
Software | SFT-OOB-LIC | 4 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0062PM | 4 | 1U Passive Front CPU Heat Sink w/ a 30-mm Wide Middle Air Channel for AMD H11 2U4N Big Twin Series Servers |
SNK-P0062PW | 4 | 1U Proprietary 93-mm Wide Passive Rear CPU Heat Sink for AMD H11 2U4N Big Twin Series Servers | |
Cable | CBL-PWCD-0578 OR | 2 | (EOL)Power Cord Type IEC (C14 to C13) 3ft (14AWG), 15A, 250V |
CBL-PWCD-0578-1 OR | PWCD,US,IEC60320 C14 TO C13,3FT,14AWG,RoHS | ||
CBL-PWCD-0578-IS | PWCD,US,IEC60320 C14 TO C13,910mm,14AWG,15A,250V,Black, RoHS | ||
*Power Supply | PWS-2K22A-1R | 2 | 1U 1200W/2200W Redundant Titanium BigTwin w/PMBus power supply, W45xH40xL480 mm, C14 inlet |
*Power Distributor | PDB-PT217-BGTWN | 1 | 2U Big Twin Power Distributor Board Support Redundant 2KW |
![]()
|
Part Number | MBD-H12DST-B | CSE-217BHQ+-R2K22BP2 |
Qty | 4 | 1 |
Description | Super H12DST-B Motherboard | 2U Chassis |
Part Number | BPN-ADP-6SATA3-1UB | BPN-SAS3-217BHQ |
Qty | 4 | 1 |
Description | Support 6 SATA HDD adaptor card for Big Twin | 2U 4-Node 24-Port 12G Backplane Supports 6x2.5" SAS3/SATA3 |
Part Number | MCP-220-00141-0B-BULK |
Qty | 24 |
Description | Black Gen3 hot-swap 2.5 inch HDD tray with lock improved EMI |
Part Number | MNL-2211-QRG |
Qty | 1 |
Description | AS -2124BT-HTR/-HNR/-HNTR/-HNC0R Quick Reference Guide |
Part Number | RSC-P-6-X2 | RSC-PR-6-X2 |
Qty | 4 | 4 |
Description | 1U LHS TwinPro riser card with one PCIe 4.0 x16 slot,HF,RoH | 1U RHS TwinPro Riser card with one PCIe 4.0 x16 slot,HF,RoH |
Part Number | SFT-OOB-LIC |
Qty | 4 |
Description | License key for enabling OOB BIOS management |
Part Number | SNK-P0062PM | SNK-P0062PW |
Qty | 4 | 4 |
Description | 1U Passive Front CPU Heat Sink w/ a 30-mm Wide Middle Air Channel for AMD H11 2U4N Big Twin Series Servers | 1U Proprietary 93-mm Wide Passive Rear CPU Heat Sink for AMD H11 2U4N Big Twin Series Servers |
Part Number | CBL-PWCD-0578 OR | CBL-PWCD-0578-1 OR | CBL-PWCD-0578-IS |
Qty | 2 | - | - |
Description | (EOL)Power Cord Type IEC (C14 to C13) 3ft (14AWG), 15A, 250V | PWCD,US,IEC60320 C14 TO C13,3FT,14AWG,RoHS | PWCD,US,IEC60320 C14 TO C13,910mm,14AWG,15A,250V,Black, RoHS |
Part Number | PWS-2K22A-1R |
Qty | 2 |
Description | 1U 1200W/2200W Redundant Titanium BigTwin w/PMBus power supply, W45xH40xL480 mm, C14 inlet |
Part Number | PDB-PT217-BGTWN |
Qty | 1 |
Description | 2U Big Twin Power Distributor Board Support Redundant 2KW |