Part Number |
Qty |
Description |
3.5" to 2.5" Converter Tray(s)
|
MCP-220-00043-0N |
- |
Hot-swap Gen-4 3.5" to 2.5" HDD tray, Black |
3.5'' to 2.5" NVMe Drive Tray(s)
|
MCP-220-00138-0B • |
- |
Tool-less Hot-swap Gen-5.5 NVMe 3.5'' to 2.5'' drive tray, Orange tab, Black |
Add-on Card for additional M.2
|
AOC-SLG3-2H8M2 |
- |
Standard LP, PCIe 3.0 x8, supports 2x NVMe/SATA M-Key M.2 Modules; RAID 0,1 |
CacheVault
|
BTR-CV3916-1U1 (For S3908) |
1 |
CacheVault for Broadcom 3908 with SuperCap mounting in 1U 40x56 fan tray |
BTR-CVPM05 • + MCP-240-00203-0N • (For S3908) |
1 |
CacheVault for Broadcom 3908 with SuperCap mounting bracket for PCIe location |
BTR-TFM8G-LSICVM02 • + MCP-240-00203-0N • (For S3108) |
1 |
CacheVault for Broadcom 3108 with SuperCap mounting bracket for PCIe location |
BTR-CV3108-1U1 (For S3108) |
1 |
CacheVault for Broadcom 3108 with SuperCap mounting in 1U 40x56 fan tray |
Cooling Fan
|
FAN-0141L4 • |
1 |
40x40x56 mm, 20.5K RPM / 17.6K RPM, Counter-rotating Fan |
DVD-ROM / DVD-RW
|
DVM-TEAC-DVDRW-SBT5 |
1 |
PHILPS slim DVD-RW SATA drive |
DVM-TEAC-DVD-SBT5 |
1 |
TEAC slim DVD-ROM SATA drive |
DVD-ROM Accessory
|
MCP-220-81502-0N + 1pc CBL-0099 • (max 1pc) |
1 |
Slim SATA DVD mounting kit |
Front Bezel
|
CSE-PTFB-813-02B |
1 |
Black Front Bezel w/ Round Venting Holes |
CSE-PTFB-813LB |
1 |
Black Front Bezel |
Hot-swap 2.5" kit (DVD slot)
|
MCP-220-81506-0N + 1pc CBL-0099 • (max 1pc) |
1 |
Single 2.5" SAS3 (12Gb/s) hot swap in slim DVD form factor |
Hot-swap 2.5" kit (FDD slot)
|
MCP-220-81504-0N |
1 |
Single 2.5" SAS3 (12Gb/s) hot swap in slim FDD form factor |
Inlet Thermal Sensor
|
MCP-280-00034-0N |
1 |
Universal Thermal sensor kit with 40cm I2C cable |
Intel VROC RAID Key for NVMe
|
AOC-VROCINTMOD |
1 |
Intel SSD Only Upgrade module; RAID 0/1/10/5 |
AOC-VROCPREMOD |
1 |
Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5 |
AOC-VROCSTNMOD |
1 |
Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10 |
NVMe Cable (Drive Bay 0-1)
|
CBL-SAST-1149-85 |
1 |
SLIMLINE x8 (RE) to 2x Oculink x4,INT, 49CM, 85 OHM |
NVMe Cable (Drive Bay 2-3)
|
CBL-SAST-1154-85 • |
1 |
SLIMLINE x8 (RE) to 2x Oculink x4,INT, 54CM, 85 OHM,RoH |
Software
|
SFT-DCMS-Single |
1 |
DataCenter Management Package (per node license) |
Storage Control Card and Cable(s)
|
AOC-S3008L-L8I |
1 |
Standard LP, 8 internal ports (12Gb/s) PCIe 3.0 x8, 63HDD; RAID 0, 1, 10 |
AOC-S3108L-H8IR-16DD • |
1 |
Standard LP, 8 Internal ports (12Gb/s) PCIe 3.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 |
AOC-S3908L-H8iR-16DD + 1x CBL-SAST-1275A-100 |
1 |
Standard LP, 8 internal ports (12Gb/s) PCIe 4.0 x8, 16HDD; RAID 0, 1, 5, 6, 10, 50, 60 |
Storage Control Card and Cable(s) (HBA)
|
AOC-S3808L-L8IT + 1x CBL-SAST-1275A-100 |
1 |
Standard LP, 8 internal ports (12Gb/s) PCIe 4.0 x8, 122HDD; HBA |
AOC-S3008L-L8E |
1 |
Standard LP, 8 internal ports (12Gb/s) PCIe 3.0 x8, 122HDD; HBA |
TPM
|
AOM-TPM-9670V-S-O • |
1 |
TPM 2.0, vertical form factor, provisioned for server |
AOM-TPM-9671V-S-O |
1 |
TPM 1.2, vertical form factor, provisioned for server |