SuperServer SYS-210P-FRDN6T

DatasheetShare IconShare

X12 2U Short-depth front I/O System with 2 x 10G & 4 x 1G ports, 2x 2.5"SATA bays and redundant DC PSU

Key Applications

  • 5G Core and Edge
  • AI Inference and Machine Learning
  • Network Function Virtualization
  • Cloud Computing

Key Features

  1. Design with compliance to NEBS-Level 3
  2. Single Socket P+ (LGA-4189) 3rd Generation Intel® Xeon® Scalable Processors
  3. 8 DIMM slots; Up to 2TB 3DS ECC DDR4-3200: RDIMM/LRDIMM/Intel® Intel® DCPMM
  4. Up to 2 PCIe 4.0 FHHL & 2 HHHL expansion slots for Accelerator Add-On-Cards
  5. Onboard 2x 10GbE ports & 4x 1GbE ports
  6. 2x 2.5" drive bays for SATA drives
  7. Redundant 600W DC -48V Power Supplies
  8. Ultra short depth, 2U Front I/O Edge Server
...
...
SYS-210P-FRDN6T
Specifications Free Remote Testing Parts List
Specifications
Product SKUs
SuperServer SYS-210P-FRDN6T
Motherboard
Super X12SPM-LN6TF
Processor
CPU
  • Single Socket P+ (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 36C/72T; Up to 60MB Cache
Note
  • Supports 85W - 270W TDP CPUs (Air Cooled)
GPU
Max GPU Count
  • Up to 2 double-width GPUs
System Memory
Memory
  • Slot Count: 8 DIMM slots
  • Max Memory (2DPC): Up to 2TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
  • View Memory Options
Memory Voltage
  • 1.2V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1 support
Chipset
  • Intel® C621A
Network Connectivity
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated BMC LAN port
  • 2 RJ45 10 GbE LAN ports (Intel® X550)
  • 4 RJ45 1 GbE LAN ports (Intel® I350-AM4)
USB
  • 2 USB 2.0 ports(front)
  • 2 USB 3.2 Gen1 ports(front)
Video
  • 1 VGA port
Management
Software
Power configurations
  • ACPI Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • CPU thermal trip support, PEPI
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-211M
Dimensions and Weight
Height
  • 3.5" (88.9 mm)
Width
  • 17.2" (436.88 mm)
Depth
  • 11.8" (298.8 mm)
Package
  • 7.4" (H) x 19.3" (W) x 23.3" (D)
Weight
  • Gross Weight: 22 lbs (10 kg)
  • Net Weight: 17 lbs (7.7 kg)
Available Color
  • Silver/Black
Front Panel
LED
  • HDD activity
  • LAN1 activity
  • LAN2 activity
  • Power status
  • System information
Buttons
  • Power On/Off 
  • UID button
Expansion Slots
PCI-Express (PCIe) Configuration
Drive Bays / Storage
Drive Bays Configuration
M.2
System Cooling
Fans
  • 4x 4-PIN PWM 8cm Fan(s)
Power Supply
Operating Environment
Environmental Spec.
  • Operating Temperature: 0°C to 35°C (32°F to 95°F)
  • Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity: 8% to 90% (non-condensing)
  • Non-operating Relative Humidity: 5% to 95% (non-condensing)
Free Remote Testing

Get free access to Supermicro’s top-end data center servers right from your browser with JumpStart

Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.

Schedule Access
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X12SPM-LN6TF

CSE-211M
1

1
Super X12SPM-LN6TF Motherboard

2U Chassis
Backplane BPN-SAS3-826TQ-B2B 1 2-Port 12Gbps Backplane for 2x2.5" SAS/SATA HDD/SSD
Cable CBL-0010L 1 9 PIN SERIAL PORT DTK CABLE, LF
CBL-0206L 2 7pin SATA (STR to STR), 48cm, PBF
CBL-CDAT-0662 1 8 Pin to 8 Pin Round SGPIO Cable, 61.5cm, 28AWG, Pinout 1-1
CBL-PWCD-0974 2 48VDC input power cable, 2M, 12AWG, 3 wires, RoHS/REACH,RoHS
CBL-PWEX-1132-20 1 MicroHi 2x2F to 2x2M MicroFit, PH3.0, 20cm,7A/p,18#,RoHS
CBL-SAST-1206LP-85 1 SlimSASLP x8 (RA) to SlimSAS x8 (STR),26CM,85 OHM,RoH
CBL-SAST-1207LP-85 1 SlimSASLP x8 (STR,RSC) to SlimSAS x8 (STR),26CM,85 OHM
CBL-SAST-1270A-85 1 2x PCIe x16 on riser PCBA to 2x x16 edge cards,90CM,RoH
CBL-CDAT-1058 1 NCSI 2x8 to 2x8, Ph2.54, 60cm shielded,28AWG, RoHS,RoHS
Power Supply PWS-601S-1R 2 1U 600W Redundant DC48V input w/PMBus power supply, W54.5xH4
Riser Card RSC-H2-68G4 1 2U LHS Hyper riser card with one PCIe 4.0 x16 and one PCIe
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0078P 1 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
Power Distributor PDB-PT211M-8824 OR 1 (EOL)2U support redundancy powers up to 800W for SC211.,RoHS
PDB-PT211M-3424 2U support redundancy powers up to 800W for SC211M with 2 Mi
*Fan FAN-0220L4 4 80x80x38 mm, 14.9K RPM Exhaust Fan for SYS-120P-FRDN6T Serve
*Front Panel FPB-TB826 1 16 pin Cable Adaptor Board for SC826
*Drive Tray(s) MCP-220-00147-0B 2 Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design)
*Rail Set MCP-290-21106-0N 1 1U height sliding rail for SC211M chassis
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
Part Number Qty Description
1U heat sink SNK-P0077V - Optional 1U heatsink if CPU < 165W
2U riser card RSC-S2R-68G4 - Optional 2U Riser card for PCIe slot 3 (PCIe x8 FHHL) if CPU < 165W
TPM security module AOM-TPM-9671V - SPI capable TPM 1.2 with Infineon 9670 controller with vertical form factor
AOM-TPM-9670V - SPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor
Standard Parts (Parts Included)
Motherboard / Chassis
Part NumberMBD-X12SPM-LN6TF CSE-211M
Qty1 1
DescriptionSuper X12SPM-LN6TF Motherboard 2U Chassis
Backplane
Part NumberBPN-SAS3-826TQ-B2B
Qty1
Description2-Port 12Gbps Backplane for 2x2.5" SAS/SATA HDD/SSD
Cable
Part NumberCBL-0010LCBL-0206LCBL-CDAT-0662CBL-PWCD-0974CBL-PWEX-1132-20CBL-SAST-1206LP-85CBL-SAST-1207LP-85CBL-SAST-1270A-85CBL-CDAT-1058
Qty121211111
Description9 PIN SERIAL PORT DTK CABLE, LF7pin SATA (STR to STR), 48cm, PBF8 Pin to 8 Pin Round SGPIO Cable, 61.5cm, 28AWG, Pinout 1-148VDC input power cable, 2M, 12AWG, 3 wires, RoHS/REACH,RoHSMicroHi 2x2F to 2x2M MicroFit, PH3.0, 20cm,7A/p,18#,RoHSSlimSASLP x8 (RA) to SlimSAS x8 (STR),26CM,85 OHM,RoHSlimSASLP x8 (STR,RSC) to SlimSAS x8 (STR),26CM,85 OHM2x PCIe x16 on riser PCBA to 2x x16 edge cards,90CM,RoHNCSI 2x8 to 2x8, Ph2.54, 60cm shielded,28AWG, RoHS,RoHS
Power Supply
Part NumberPWS-601S-1R
Qty2
Description1U 600W Redundant DC48V input w/PMBus power supply, W54.5xH4
Riser Card
Part NumberRSC-H2-68G4
Qty1
Description2U LHS Hyper riser card with one PCIe 4.0 x16 and one PCIe
Software
Part NumberSFT-OOB-LIC
Qty1
DescriptionLicense key for enabling OOB BIOS management
Heatsink / Retention
Part NumberSNK-P0078P
Qty1
Description2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
Power Distributor
Part NumberPDB-PT211M-8824 OR PDB-PT211M-3424
Qty1-
Description(EOL)2U support redundancy powers up to 800W for SC211.,RoHS2U support redundancy powers up to 800W for SC211M with 2 Mi
*Fan
Part NumberFAN-0220L4
Qty4
Description80x80x38 mm, 14.9K RPM Exhaust Fan for SYS-120P-FRDN6T Serve
*Front Panel
Part NumberFPB-TB826
Qty1
Description16 pin Cable Adaptor Board for SC826
*Drive Tray(s)
Part NumberMCP-220-00147-0B
Qty2
DescriptionBlack gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design)
*Rail Set
Part NumberMCP-290-21106-0N
Qty1
Description1U height sliding rail for SC211M chassis
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Optional Parts List
1U heat sink
Part NumberSNK-P0077V
Qty-
DescriptionOptional 1U heatsink if CPU < 165W
2U riser card
Part NumberRSC-S2R-68G4
Qty-
DescriptionOptional 2U Riser card for PCIe slot 3 (PCIe x8 FHHL) if CPU < 165W
TPM security module
Part NumberAOM-TPM-9671VAOM-TPM-9670V
Qty--
DescriptionSPI capable TPM 1.2 with Infineon 9670 controller with vertical form factorSPI capable TPM 2.0 with Infineon 9670 controller with vertical form factor

IoT SuperServer SYS-210P-FRDN6T

Certain products may not be available in your region