SuperServer SYS-620H-TN12R

DatasheetShare IconShare

2U Hyper with 12 NVMe/SAS/SATA bays and up to 8 PCIe slots with GPU support

SYS-620H-TN12R Main SYS-620H-TN12R Angle SYS-620H-TN12R Top SYS-620H-TN12R Front SYS-620H-TN12R Rear
Integrated Board: X12DHM-6
Learn more

Key Applications

  • Virtualization
  • Software-defined Storage
  • AI Inference and Machine Learning
  • Cloud Computing
  • Enterprise Server

Key Features

  1. Dual Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable Processors
  2. 32 DIMM Slots; Up to 8TB DRAM; Up to 8TB Intel® Optane™ Persistent Memory (up to 12TB with DRAM); 3200/2933/2666 ECC DDR4 LRDIMM;RDIMM; Intel® Optane™ Persistent Memory 200 series
  3. Optional PCIe slot configurations up to 8 PCIe 4.0 x8 or 4 PCIe 4.0 x16 slots with support for double-width GPU/Accelerator cards
  4. Flexible networking options with up to 2 AIOM networking slots (OCP NIC 3.0 compatible)
  5. 4 heavy duty hot-swap fans with optimal fan speed control
...
...
SYS-620H-TN12R
Specifications Free Remote Testing Parts List
Specifications
Product SKUs
SuperServer SYS-620H-TN12R
Motherboard
Super X12DHM-6
Processor
CPU
  • Dual Socket P+ (LGA-4189)
  • 3rd Gen Intel® Xeon® Scalable processors
Core Count
  • Up to 40C/80T; Up to 60MB Cache per CPU
Note
  • Supports up to 270W TDP CPUs (Air Cooled)
GPU
Max GPU Count
  • Up to 4 double-width GPUs
System Memory
Memory
  • Slot Count: 32 DIMM slots
  • Max Memory (2DPC): Up to 8TB 3200MT/s ECC DDR4
  • Supports Intel® Optane™ persistent memory 200 series
  • View Memory Options
Memory Voltage
  • 1.2V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1/5/10 support
NVMe
Chipset
  • Intel® C621A
Network Connectivity
  • 2 RJ45 1GbE with Intel® I350-AM2 (optional)
  • 4 RJ45 1GbE with Intel® I350-AM4 (optional)
  • 4 SFP 1GbE with Intel® I350-AM4 (optional)
  • 2 RJ45 10GBASE-T with Intel® X550-AT2 (optional)
  • 2 SFP+ 10GbE with Intel® X710-BM2 (optional)
  • 4 SFP+ 10GbE with Intel® XL710-BM1 (optional)
  • 4 SFP+ 10GbE with Intel® X710-TM4 (optional)
  • 2 SFP28 25GbE with Broadcom® BCM57414 (optional)
  • 4 SFP28 25GbE (optional)
  • 2 QSFP28 100GbE with Broadcom® BCM57508 (optional)
  • View AIOM Options
  • View AOC Options
System BIOS
BIOS Type
  • AMI 256MB SPI Flash
Management
Software
Power configurations
  • Power-on mode for AC power recovery
  • ACPI Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-HS829-R1K24P
Dimensions and Weight
Height
  • 3.5" (88.9 mm)
Width
  • 17.2" (437 mm)
Depth
  • 31.6" (803 mm)
Package
  • 10.4" (H) x 23.8" (W) x 43.6" (D)
Weight
  • Gross Weight: 63 lbs (28.6 kg)
  • Net Weight: 37 lbs (16.8 kg)
Available Color
  • N/A
Front Panel
LED
  • HDD activity
  • LAN1 activity
  • Power
  • System information
Buttons
  • Power On/Off 
  • UID button
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default*
    • 8 PCIe 4.0 x8 (in x16) FH/10.5"L slots
    • 2 PCIe 4.0 x16 AIOM slots (OCP 3.0 compatible)
  • Option A*
    • 2 PCIe 4.0 x8 (in x16) FH/10.5"L slots
    • 3 PCIe 4.0 x16 FH/10.5"L slots
    • 2 PCIe 4.0 x16 AIOM slots (OCP 3.0 compatible)
  • (*Requires additional parts, please see the optional parts list for details. For more details on PCIe slot configuration options, please refer to the system callout images above.)
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 12 bays
    • 12 front hot-swap 3.5" NVMe*/SAS*/SATA* drive bays
  • (*NVMe/SAS/SATA support may require additional storage controller and/or cables)
  • View NVMe Options
  • View Drive Options
M.2
System Cooling
Fans
  • 4x 8cm heavy duty fans with optimal fan speed control
Air Shroud
  • 2 Air Shrouds
Power Supply
Operating Environment
Environmental Spec.
  • Operating Temperature: 10°C to 35°C (50°F to 95°F)
  • Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity: 8% to 90% (non-condensing)
  • Non-operating Relative Humidity: 5% to 95% (non-condensing)
Free Remote Testing

Get free access to Supermicro’s top-end data center servers right from your browser with JumpStart

Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.

Schedule Access
Resources & Downloads
Parts List
Optional Parts List
Part Number Qty Description
2nd AIOM/OCP NIC 3.0 Slot Refer to User's Manual - AIOM slot A2 kit
Cable Management Arm + Rail Set MCP-290-00168-0N + MCP-290-11901-0N - 7.5" cable management arm + 41" long ball-bearing rail set
Drive Bay Configuration Options Refer to User's Manual - Drive bay configuration options for NVMe, SAS, or SATA support
Global Services & Support OS4HR3/2/1 - Gold Level, 3/2/1-year onsite 24x7x4 SLA
OSNBD3/2/1 - Silver Level, 3/2/1-year onsite NBD SLA
SMSAD3/2/1 - Bronze Level, 3/2/1-year 3BD SLA
Intel® VROC RAID Key Options AOC-VROCINTMOD 1 Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)
AOC-VROCSTNMOD 1 Intel VROC Standard, RAID 0, 1, 10
AOC-VROCPREMOD 1 Intel VROC Premium, RAID 0, 1, 5, 10
PCIe Slot Configuration Options Refer to User's Manual - PCIe slot configuration options to enable PCIe slots 1-8
Power Supply MCP-250-00025-0N - Single Power Supply Dummy Cover (W73.5mm) for 1U/2U Hyper Chassis
PWS-2K63A-1R - 1U 2600W Redundant Power Supply, 80 PLUS Titanium, W73.5xH40xL265mm, C20 inlet
PWS-1K63A-1R - 1U 1000W/1600W Redundant Power Supply, 80 PLUS Titanium, W73.5xH40xL265mm, C14 inlet
PWS-1K24A-1R (included in the system) - 1U 800W/1200W Redundant Power Supply, 80 PLUS Titanium, W73.5xH40xL265mm, C14 inlet
Rail Set MCP-290-11903-0N 1 30.5" ball-bearing rail set for Hyper servers
MCP-290-11902-0N (included in the system ) 1 35.25" ball-bearing rail set for Hyper servers
MCP-290-11901-0N 1 41" ball-bearing rail set for Hyper servers
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
Trusted Platform Module Options AOM-TPM-9671V-O 1 SPI capable vertical TPM 1.2
AOM-TPM-9670V-O 1 SPI capable vertical TPM 2.0
AOM-TPM-9670V-S-FIPS-O 1 AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS
Optional Parts List
2nd AIOM/OCP NIC 3.0 Slot
Part NumberRefer to User's Manual
Qty-
DescriptionAIOM slot A2 kit
Cable Management Arm + Rail Set
Part NumberMCP-290-00168-0N + MCP-290-11901-0N
Qty-
Description7.5" cable management arm + 41" long ball-bearing rail set
Drive Bay Configuration Options
Part NumberRefer to User's Manual
Qty-
DescriptionDrive bay configuration options for NVMe, SAS, or SATA support
Global Services & Support
Part NumberOS4HR3/2/1OSNBD3/2/1SMSAD3/2/1
Qty---
DescriptionGold Level, 3/2/1-year onsite 24x7x4 SLASilver Level, 3/2/1-year onsite NBD SLABronze Level, 3/2/1-year 3BD SLA
Intel® VROC RAID Key Options
Part NumberAOC-VROCINTMODAOC-VROCSTNMODAOC-VROCPREMOD
Qty111
DescriptionIntel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)Intel VROC Standard, RAID 0, 1, 10Intel VROC Premium, RAID 0, 1, 5, 10
PCIe Slot Configuration Options
Part NumberRefer to User's Manual
Qty-
DescriptionPCIe slot configuration options to enable PCIe slots 1-8
Power Supply
Part NumberMCP-250-00025-0NPWS-2K63A-1RPWS-1K63A-1RPWS-1K24A-1R (included in the system)
Qty----
DescriptionSingle Power Supply Dummy Cover (W73.5mm) for 1U/2U Hyper Chassis1U 2600W Redundant Power Supply, 80 PLUS Titanium, W73.5xH40xL265mm, C20 inlet1U 1000W/1600W Redundant Power Supply, 80 PLUS Titanium, W73.5xH40xL265mm, C14 inlet1U 800W/1200W Redundant Power Supply, 80 PLUS Titanium, W73.5xH40xL265mm, C14 inlet
Rail Set
Part NumberMCP-290-11903-0NMCP-290-11902-0N (included in the system )MCP-290-11901-0N
Qty111
Description30.5" ball-bearing rail set for Hyper servers35.25" ball-bearing rail set for Hyper servers41" ball-bearing rail set for Hyper servers
Software
Part NumberSFT-DCMS-Single
Qty1
DescriptionDataCenter Management Package (per node license)
Trusted Platform Module Options
Part NumberAOM-TPM-9671V-OAOM-TPM-9670V-OAOM-TPM-9670V-S-FIPS-O
Qty111
DescriptionSPI capable vertical TPM 1.2SPI capable vertical TPM 2.0AOM-TPM-9670V-S-FIPS TPM 2.0 support TAA and FIPS

Hyper SuperServer SYS-620H-TN12R

Certain products may not be available in your region