Enclosure | Power Supply*** | Blade Module Capacity | Intel-based Blade | AMD-Based Blade | Module | Remark |
---|---|---|---|---|---|---|
MBE-620E |
| 20 Blades | N/A | Support up to:
| ||
MBE-314E |
| 14 Blades |
| N/A |
| Support up to:
|
MBE-628L |
| 28 Blades |
| N/A |
| Support up to:
|
MBE-628E |
| 28 Blades |
| N/A |
| Support up to:
|
* MBE-628L enclosure supports one CMM, the blade BMC redundant will be de-activated.
MBE-628L enclosure supports 1GbE or 2.5GbE switch.
All of the NICs for MBI-6128R-T2/T2X, MBI-6118G-T41X, MBI-6218G-T41X connect to A1 switch.
** MBE-628E/314E enclosure supports up to 2 switches, each switch supports 56 ports.
There are total 2 switches per MBE-628E/314E will be needed to support all of 1st NIC of Atom nodes, the 2nd NIC for each Atom nodes will not be able to enable.
*** Power supply's available power. For example, 4x 2000W means total available power is 8000W @ 220V input power.
Check the Power Supply page for output power.
**** One CMM support only
***** Need to work with PWS-2K01A-BR
^ Support MBM-GEM-004 (GEM-004 can support only single-node servers with dual ports in 6U enclosure)
† Please contact sales rep.
Model Name | Motherboard | Max. CPU TDP | PSU | CPU Heat Sink |
---|---|---|---|---|
MBI-311A-1T2N | B4SA1-CPU | 65W*** | 2.2KW/3.0KW | SNK-P1041V |
MBI-311A-1C2 | B4SA1-CPU | 65W*** | 2.2KW/3.0KW | SNK-P1041V |
MBI-311C-1T2N | B4SC1-CPU | 95W*** | 2.2KW/3.0KW | SNK-P1041V |
MBI-311C-1C2 | B4SC1-CPU | 95W*** | 2.2KW/3.0KW | SNK-P1041V |
MBI-310T-4T2N | B3ST1-CPU-001 | 95W*** | 1.6KW**** /2.0KW**** /2.2KW | SNK-P1040V |
MBI-310T-4C2 | B3ST1-CPU-001 | 95W*** | 1.6KW**** /2.0KW**** /2.2KW | SNK-P1040V |
MBI-6219M-2N | B2SC2-TF | 95W*** | 1.6KW**** /2.0KW**** /2.2KW | SNK-P1040V |
MBI-6219B-T41N | B2SD2-8C-TF | 65W | 1.6KW**** /2.0KW**** /2.2KW | Included |
MBI-6219B-T63N | B2SD2-12C-TF | 75W | 1.6KW**** /2.0KW**** /2.2KW | Included |
MBI-6219B-T83N | B2SD2-16C-TF | 100W | 1.6KW**** /2.0KW**** /2.2KW | Included |
MBI-6119M-C2 | B2SC1-CPU | 95W*** | 1.6KW**** /2.0KW**** /2.2KW | SNK-P1040V |
MBI-6119M-T2N | B2SC1-CPU | 95W*** | 1.6KW**** /2.0KW**** /2.2KW | SNK-P1040V |
MBI-6119G-T8HX (EOL) | B2SS1-H-MTF | 65W | 2.0KW/2.2KW | Included |
MBI-6219G-T8HX (EOL) | B2SS2-H-MTF | 65W | 2.0KW/2.2KW | Included |
MBI-6119G-T7LX (EOL) | B2SS1-MTF | 45W | 1.6KW/2.0KW/2.2KW | Included |
MBI-6219G-T7LX (EOL) | B2SS1-MTF | 45W | 1.6KW/2.0KW/2.2KW | Included |
MBI-6119G-C4 (EOL) | B2SS1-CF | 80W* | 1.6KW**** /2.0KW**** /2.2KW |
|
MBI-6119G-C2 (EOL) | B2SS1-CPU | 80W* | 1.6KW**** /2.0KW**** /2.2KW |
|
MBI-6119G-T4 (EOL) | B2SS1-F | 80W* | 1.6KW**** /2.0KW**** /2.2KW |
|
MBI-6219G-T (EOL) | B2SS2-F-P | 80W** | 1.6KW**** /2.0KW**** /2.2KW |
|
MBI-6118G-T81X (EOL) | B1SD1-16C-TF | 65W | 1.6KW/2.0KW/2.2KW | Included |
MBI-6218G-T81X (EOL) | B1SD2-16C-TF | 65W | 1.6KW/2.0KW/2.2KW | Included |
MBI-6118G-T41X (EOL) | B1SD1-TF | 45W | 1.6KW/2.0KW/2.2KW | Included |
MBI-6218G-T41X (EOL) | B1SD2-TF | 45W | 1.6KW/2.0KW/2.2KW | Included |
MBI-6118D-T2H (EOL) | B1SL1-HF | 84W | 1.6KW/2.0KW/2.2KW | SNK-P0047PSR |
MBI-6118D-T4H (EOL) | B1SL1-HF | 84W | 1.6KW/2.0KW/2.2KW | SNK-P0047PSR |
MBI-6118D-T2 (EOL) | B1SL1-F | 84W | 1.6KW/2.0KW/2.2KW | SNK-P0047PSR |
MBI-6118D-T4 (EOL) | B1SL1-F | 84W | 1.6KW/2.0KW/2.2KW | SNK-P0047PSR |
MBI-6128R-T2X (EOL) | B1DRi | 90W/120W | 1.6KW (90W CPU) 2.0KW/2.2KW (120W CPU) | SNK-P0047PSRM (CPU2 Front) / SNK-P0047PSR or SNK-P0047PSRK (CPU1 Rear) |
MBI-6128R-T2 (EOL) | B1DRi | 90W/120W | 1.6KW (90W CPU) 2.0KW/2.2KW (120W CPU) | SNK-P0047PSRM (CPU2 Front) / SNK-P0047PSR or SNK-P0047PSRK (CPU1 Rear) |
MBI-6418A-T7H (EOL) | B1SA4-2750F | 20W | 1.6KW | Included |
MBI-6418A-T5H (EOL) | B1SA4-2550F | 14W | 1.6KW | Included |
* To support E3-1285 V6, environment temperature of 25°C/77°F, 2.0KW (AC/DC) or higher Power Supply and 2x 7mm HDD or less are mandatory.
** 1.6KW @ 30°C with 2 SSD Installed or 2.0KW (AC/DC) or higher Power Supply is mandatory. To support E3-1285 V6, please contact Sales Rep. or Technical Support for thermal limitation.
*** To support 95W CPU, environment temperature of 23°C/73°F and 2.0KW (AC/DC) or higher Power Supply are mandatory.
**** Please contact Sales Rep. or Technical Support for thermal limitation.