Part Number | Qty | Description | |
2U Cable Management Arm | MCP-290-00128-0N + MCP-290-00127-0N | 1 | 2U Supermicro Cable Management Arm 2nd Gen + rail set |
Additional HDD Kit | MCP-240-82922-0N-OEM | - | Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U |
CacheVault(s) | BTR-TFM8G-LSICVM02 + BKT-BBU-BRACKET-05 | - | CacheVault for Broadcom 3108 + Supercap mounting bracket for PCIe location |
BTR-TFM8G-LSICVM02 + MCP-240-00127-0N + MCP-220-00043-0N | - | CacheVault for Broadcom 3108 + Supercap mounting bracket for 2.5" HDD location + 3.5"-to-2.5" converter drive tray | |
BTR-CVPM05 + BKT-BBU-BRACKET-05 | - | Cache Vault for 3908/3916 controller + Supercap mounting bracket for PCIe location | |
BTR-CVPM05 + MCP-240-00127-0N + MCP-220-00043-0N | - | Cache Vault for 3908/3916 controller + Supercap mounting bracket for 2.5" HDD location + 3.5"-to-2.5" converter drive tray | |
Global Services & Support | OS4HR3/2/1 | - | 3/2/1-year onsite 24x7x4 service |
OSNBD3/2/1 | - | 3/2/1-year onsite NBD service | |
GPU Kit | MCP-310-00091-0B | 1 | Ultra 2U GPU Air Shroud Kit for AMD |
SNK-P0062P | 2 | 1U Passive CPU Heat Sink for AMD Socket SP3 Processors | |
Hot-swap 3.5" to 2.5" Hard Disk Drive Tray | MCP-220-00118-0B | - | STD Black hot-swap tool-less 3.5"-to-2.5" converter drive tray |
MCP-220-00043-0N | - | STD Black hot-swap screw type 3.5"-to-2.5" converter drive tray | |
M.2 via AOC | AOC-SLG3-2M2 | 1 | LP, PCIe3 x8, Dual port NVMe M.2 carrier |
AOC-SLG3-2H8M2 | 1 | 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS | |
Optional Kit for NVMe solution | MCP-220-00116-0B | 1~4 | Black gen-5 3.5"-to-2.5" NVMe drive tray, Orange tab (for hotswap NVMe drive) |
MCP-220-00138-0B | 1~4 | Black gen-5.5 tool-less NVMe 3.5"-to-2.5" drive tray, Orange tab | |
Riser Card | RSC-W2-8888G4 | - | 2U LHS WIO Riser card with four PCIe 4.0 x8 slots,HF,RoHS |
SATADOM | MEM-IDSAVS3-032G | - | SATA3DOM SL 3SE 32GB SLC LP No Pin8 Vcc Support (S130710) |
MEM-IDSAVE1-064G | - | SATA3DOM SL 3IE3 V2 64GB iSLC LP Pin8 VCC NH (S17411i) | |
MEM-IDSAVM8A-256G | - | SATA3DOM ML 3ME3 V2 256GB MLC LP Pin8 VCC NH (S17411) | |
MEM-IDSAVM8A-128G | - | SATA3DOM SL 3ME3 V2 128GB MLC LP Pin8 VCC NH (S17411) | |
MEM-IDSAVT1-256G | - | IND SATA3DOM SL 3TE7 256GB 3D TLC Pin8VCC Vertical LP | |
SSD-DM128-SMCMVN1 | - | SMC SATADOM, 128GB, SATA 6Gb/s, MLC, uSSD, 15nm,HF,RoHS/REACH | |
SSD-DM480-SMCMVN1 | - | SMC SATADOM,480GB,SATA 6Gb/s,3D TLC,uSSD,HF,RoHS | |
SSD-DM064-SMCMVN1 | - | SMC SATADOM,64GB,SATA 6Gb/s,MLC,uSSD,15nm,HF,RoHS | |
SSD-DM032-SMCMVN1 | - | SMC SATADOM,32GB,SATA 6Gb/s,MLC,uSSD,15nm,HF,RoHS | |
MEM-IDSAVS4-032G | - | SATA3DOM SL 3SE4 32GB SLC LP Pin8 VCC NH (L17725) | |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Storage Controller Card and Cable(s) | AOC-S3108L-H8iR/16DD + 2x CBL-SAST-1285-100 (support up to 8 SAS3 HDD) | - | CARD: Std LP, 8 WIO L ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM |
AOC-SAS3-9361-16I + 3x CBL-SAST-1285-100 (support up to 12 SAS3 HDD) | - | CARD: MegaRAID SAS 9361-16i; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | |
AOC-S3616L-L16IT + 3x CBL-SAST-1285-100 (support up to 12 SAS3 HDD) | - | CARD: 16 int 12Gb/s ports, 16xGen3, IOC/IT mode - LP; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | |
AOC-S3808L-L8iT + 1x CBL-SAST-1264F-100 (support up to 8 SAS3 HDD) | - | CARD: 8 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD w/ exp,RoHS; CABLE: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM | |
AOC-S3908L-H8iR-16DD + 1x CBL-SAST-1264F-100 (support up to 8 SAS3 HDD) | - | CARD: 8 int 12Gb/s ports, x8 Gen4, ROC - LP, 16 HDD w/ exp,RoHS; CABLE: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM | |
AOC-S3816L-L16iT + 1x CBL-SAST-1264F-100 + 1x CBL-SAST-1265F-100 (support up to 12 SAS3 HDD) | - | CARD: 16 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD w/ exp,RoHS; CABLE 1: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM; CABLE 2: Slimline x8 (STR) to Slimline x4 (STR),64CM,100 OHM,RoHS | |
AOC-S3916L-H16iR-32DD + 1x CBL-SAST-1264F-100 + 1x CBL-SAST-1265F-100 (support up to 12 SAS3 HDD) | - | CARD: 16 int 12Gb/s ports, x8 Gen4, ROC - LP, 32 HDD w/ exp,RoHS; CABLE 1: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM; CABLE 2: Slimline x8 (STR) to Slimline x4 (STR),64CM,100 OHM,RoHS | |
AOC-S3008L-L8i + 2x CBL-SAST-1285-100 (support up to 8 SAS3 HDD) | - | CARD: Std LP, 8 WIO L ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | |
AOC-S3008L-L8e + 2x CBL-SAST-1285-100 (support up to 8 SAS3 HDD) | - | CARD: Std LP, 8 WIO L ports, 12Gb/s per port- Gen3, 122HDD, HBA; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | |
TPM | AOM-TPM-9665H | - | Horizontal TPM using SLB9665 Chipset supporing TPM2.0,RoHS/REACH |
AOM-TPM-9655V | - | Vertical TPM with Infineon 9655 TCG 1.2 | |
Ultra 2U Front Bezel | MCP-210-82601-0B | - | Black Front Bezel for 826 chassis |
Ultra Riser Card Kit #1 | MCP-240-82925-0N | 1 | Ultra I/O bracket for SC829U, 219U (Square Opening) |
AOC-2UR668G4* | 1 | [* No LAN; requires additional SMCI NIC card] 2U Ultra Riser with 2x PCIe 4.0 x16 and 1x PCIe 4.0 x8 (internal, in x16),RoHS | |
Ultra Riser Card Kit #2 | MCP-240-82914-0N | 1 | Ultra I/O bracket for SC829U, 219U (B2TS) |
AOC-2UR68G4-m2TS | 1 | 2U Ultra Riser 2-port 25GbE SFP28, Mellanox CX-6 LX, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0x8 (internal, in x16),RoHS |
Part Number | MCP-290-00128-0N + MCP-290-00127-0N |
Qty | 1 |
Description | 2U Supermicro Cable Management Arm 2nd Gen + rail set |
Part Number | MCP-240-82922-0N-OEM |
Qty | - |
Description | Rear 2x 2.5" HDDs riser bracket kit for SC829U/219U |
Part Number | BTR-TFM8G-LSICVM02 + BKT-BBU-BRACKET-05 | BTR-TFM8G-LSICVM02 + MCP-240-00127-0N + MCP-220-00043-0N | BTR-CVPM05 + BKT-BBU-BRACKET-05 | BTR-CVPM05 + MCP-240-00127-0N + MCP-220-00043-0N |
Qty | - | - | - | - |
Description | CacheVault for Broadcom 3108 + Supercap mounting bracket for PCIe location | CacheVault for Broadcom 3108 + Supercap mounting bracket for 2.5" HDD location + 3.5"-to-2.5" converter drive tray | Cache Vault for 3908/3916 controller + Supercap mounting bracket for PCIe location | Cache Vault for 3908/3916 controller + Supercap mounting bracket for 2.5" HDD location + 3.5"-to-2.5" converter drive tray |
Part Number | OS4HR3/2/1 | OSNBD3/2/1 |
Qty | - | - |
Description | 3/2/1-year onsite 24x7x4 service | 3/2/1-year onsite NBD service |
Part Number | MCP-310-00091-0B | SNK-P0062P |
Qty | 1 | 2 |
Description | Ultra 2U GPU Air Shroud Kit for AMD | 1U Passive CPU Heat Sink for AMD Socket SP3 Processors |
Part Number | MCP-220-00118-0B | MCP-220-00043-0N |
Qty | - | - |
Description | STD Black hot-swap tool-less 3.5"-to-2.5" converter drive tray | STD Black hot-swap screw type 3.5"-to-2.5" converter drive tray |
Part Number | AOC-SLG3-2M2 | AOC-SLG3-2H8M2 |
Qty | 1 | 1 |
Description | LP, PCIe3 x8, Dual port NVMe M.2 carrier | 2x Hybrid NVMe/SATA M.2 RAID Carrier, Standard LP,RoHS |
Part Number | MCP-220-00116-0B | MCP-220-00138-0B |
Qty | 1~4 | 1~4 |
Description | Black gen-5 3.5"-to-2.5" NVMe drive tray, Orange tab (for hotswap NVMe drive) | Black gen-5.5 tool-less NVMe 3.5"-to-2.5" drive tray, Orange tab |
Part Number | RSC-W2-8888G4 |
Qty | - |
Description | 2U LHS WIO Riser card with four PCIe 4.0 x8 slots,HF,RoHS |
Part Number | MEM-IDSAVS3-032G | MEM-IDSAVE1-064G | MEM-IDSAVM8A-256G | MEM-IDSAVM8A-128G | MEM-IDSAVT1-256G | SSD-DM128-SMCMVN1 | SSD-DM480-SMCMVN1 | SSD-DM064-SMCMVN1 | SSD-DM032-SMCMVN1 | MEM-IDSAVS4-032G |
Qty | - | - | - | - | - | - | - | - | - | - |
Description | SATA3DOM SL 3SE 32GB SLC LP No Pin8 Vcc Support (S130710) | SATA3DOM SL 3IE3 V2 64GB iSLC LP Pin8 VCC NH (S17411i) | SATA3DOM ML 3ME3 V2 256GB MLC LP Pin8 VCC NH (S17411) | SATA3DOM SL 3ME3 V2 128GB MLC LP Pin8 VCC NH (S17411) | IND SATA3DOM SL 3TE7 256GB 3D TLC Pin8VCC Vertical LP | SMC SATADOM, 128GB, SATA 6Gb/s, MLC, uSSD, 15nm,HF,RoHS/REACH | SMC SATADOM,480GB,SATA 6Gb/s,3D TLC,uSSD,HF,RoHS | SMC SATADOM,64GB,SATA 6Gb/s,MLC,uSSD,15nm,HF,RoHS | SMC SATADOM,32GB,SATA 6Gb/s,MLC,uSSD,15nm,HF,RoHS | SATA3DOM SL 3SE4 32GB SLC LP Pin8 VCC NH (L17725) |
Part Number | SFT-DCMS-Single |
Qty | 1 |
Description | DataCenter Management Package (per node license) |
Part Number | AOC-S3108L-H8iR/16DD + 2x CBL-SAST-1285-100 (support up to 8 SAS3 HDD) | AOC-SAS3-9361-16I + 3x CBL-SAST-1285-100 (support up to 12 SAS3 HDD) | AOC-S3616L-L16IT + 3x CBL-SAST-1285-100 (support up to 12 SAS3 HDD) | AOC-S3808L-L8iT + 1x CBL-SAST-1264F-100 (support up to 8 SAS3 HDD) | AOC-S3908L-H8iR-16DD + 1x CBL-SAST-1264F-100 (support up to 8 SAS3 HDD) | AOC-S3816L-L16iT + 1x CBL-SAST-1264F-100 + 1x CBL-SAST-1265F-100 (support up to 12 SAS3 HDD) | AOC-S3916L-H16iR-32DD + 1x CBL-SAST-1264F-100 + 1x CBL-SAST-1265F-100 (support up to 12 SAS3 HDD) | AOC-S3008L-L8i + 2x CBL-SAST-1285-100 (support up to 8 SAS3 HDD) | AOC-S3008L-L8e + 2x CBL-SAST-1285-100 (support up to 8 SAS3 HDD) |
Qty | - | - | - | - | - | - | - | - | - |
Description | CARD: Std LP, 8 WIO L ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | CARD: MegaRAID SAS 9361-16i; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | CARD: 16 int 12Gb/s ports, 16xGen3, IOC/IT mode - LP; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | CARD: 8 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD w/ exp,RoHS; CABLE: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM | CARD: 8 int 12Gb/s ports, x8 Gen4, ROC - LP, 16 HDD w/ exp,RoHS; CABLE: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM | CARD: 16 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP, 122 HDD w/ exp,RoHS; CABLE 1: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM; CABLE 2: Slimline x8 (STR) to Slimline x4 (STR),64CM,100 OHM,RoHS | CARD: 16 int 12Gb/s ports, x8 Gen4, ROC - LP, 32 HDD w/ exp,RoHS; CABLE 1: Slimline x8 (STR) to 2x Slimline x4 (STR),FFC,64/64CM; CABLE 2: Slimline x8 (STR) to Slimline x4 (STR),64CM,100 OHM,RoHS | CARD: Std LP, 8 WIO L ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM | CARD: Std LP, 8 WIO L ports, 12Gb/s per port- Gen3, 122HDD, HBA; CABLE: Slimline x4 (STR) to MiniSAS HD (STR) x4,85CM,100 OHM |
Part Number | AOM-TPM-9665H | AOM-TPM-9655V |
Qty | - | - |
Description | Horizontal TPM using SLB9665 Chipset supporing TPM2.0,RoHS/REACH | Vertical TPM with Infineon 9655 TCG 1.2 |
Part Number | MCP-210-82601-0B |
Qty | - |
Description | Black Front Bezel for 826 chassis |
Part Number | MCP-240-82925-0N | AOC-2UR668G4* |
Qty | 1 | 1 |
Description | Ultra I/O bracket for SC829U, 219U (Square Opening) | [* No LAN; requires additional SMCI NIC card] 2U Ultra Riser with 2x PCIe 4.0 x16 and 1x PCIe 4.0 x8 (internal, in x16),RoHS |
Part Number | MCP-240-82914-0N | AOC-2UR68G4-m2TS |
Qty | 1 | 1 |
Description | Ultra I/O bracket for SC829U, 219U (B2TS) | 2U Ultra Riser 2-port 25GbE SFP28, Mellanox CX-6 LX, 1 PCIe 4.0 x8 (in x16), 1 PCIe 4.0 x16 and 1 PCIe 4.0x8 (internal, in x16),RoHS |