Certain products may not be available in your region
Key Applications
Key Features
...
...
|
|
|
Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.
Schedule AccessClick the button to download the latest BIOS for this product. If you are looking for an older-revision BIOS, please contact our technical support.
* Please do not download / upgrade the BIOS/Firmware UNLESS your system has a BIOS/Firmware-related issue. Flashing the wrong BIOS/Firmware can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS/Firmware update.
Click the button to download the latest BMC firmware for this product. If you are looking for an older-revision BIOS, please contact our technical support.
* Please do not download / upgrade the BMC/Firmware UNLESS your system has a BMC/Firmware-related issue. Flashing the wrong BMC/Firmware can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BMC/Firmware update.
Download the latest manuals for SSG-520P-ACTR12H.
Type: User's Manual
Revision: 1.0a
Download the latest Quick References for SSG-520P-ACTR12H.
Type: PDF
Revision: 1.00
Check out the specifications webpage for SSG-520P-ACTR12H.
Check out the certification webpage for SSG-520P-ACTR12H.
Standard Parts (Parts Included) | |||
Part Number | Qty | Description | |
Motherboard / Chassis |
MBD-X12SPI-TF CSE-826BTS-R802LPB |
1 1 |
Super X12SPI-TF Motherboard 2U Chassis |
Add-on Card / Module | AOC-S3916L-H16IR-32DD-P | 1 | 16 int 12Gb/s ports, x8 Gen4, ROC - LP, 32HDDw/exp,RoHS |
Backplane | BPN-SAS3-LA26A-N12 | 1 | 2U 12-Slot LFF Backplane Supports 12 x SAS3/SATA3/NVMe4 Stor |
Cable | CBL-CDAT-0728 | 1 | 4 Pin to 4 Pin I2C Cable, 65cm, 26AWG, 4 Wires, Pinout 1-1 |
CBL-SAST-1249-100 | 1 | Slimline x8 (STR) to 2x Slimline x4 (STR),50CM,100 OHM, | |
CBL-SAST-1281-100 | 1 | Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM, | |
CBL-CDAT-0921-85 | 1 | I2C,(1x4F to 1x4F)/P2.5,85CM,26AWG,RoHS | |
CBL-PWCD-0160-IS | 2 | PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH | |
CBL-PWEX-1069 | 3 | PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,30CM,22AWG,5A/pin,RoHS | |
Parts | MCP-260-00042-1N | 1 | Standard I/O Shield for X12SPi with EMI Gasket |
Manual | MNL-2361-QRG | 1 | 520P-ACTR12L/H Quick Reference Guide |
Software | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0078P | 1 | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-802A-1R | 2 | 1U 800W 100-240Vac/47-63Hz, and DC240 input |
*Power Distributor | PDB-PT826-8824 | 1 | PDB with longer 24pin for SC826B |
*Front Panel | FPB-TB826-T | 1 | Chassis transfer board for SC826 |
*Drive Tray(s) | MCP-220-00075-0B | 12 | Black gen 5.5 hot-swap 3.5" HDD tray |
*Rear Window | MCP-240-82608-0N | 1 | 216B/826B LP rear window,RoHS/REACH,PBF |
*Rail Set | MCP-290-00053-0N | 1 | Rail set, quick/quick, default for 2,3U 17.2"W |
MCP-290-00060-0N | 1 | Threaded rail adapter default for round hole rack | |
*Air Shroud | MCP-310-29001-0N | 1 | SC825/826/216/213 Intel DP X9,X8 air shroud 13.68x13/12x13 |
*Fan | FAN-0166L4 OR | 3 | 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4) |
FAN-0206L4 | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers | ||
![]()
|
Optional Parts List | |||
Part Number | Qty | Description | |
2x 2.5" NVMe Cage (Rear) | MCP-220-82619-0N + 1x CBL-SAST-1264-85 | 1 | Rear hot-swap 2x 2.5" NVMe drive kit |
2x 2.5" SATA/SAS Cage (Rear) | MCP-220-82616-0N | 1 | Rear hot-swap 2x 2.5" SATA/SAS drive kit |
3.5" to 2.5" Converter Tray(s) | MCP-220-00043-0N | - | Hot-swap Gen-4 3.5" to 2.5" HDD tray, Black |
CacheVault | BTR-CVPM05 & MCP-240-00203-0N (For S3916) | 1 | CacheVault for Broadcom 3916 with SuperCap mounting bracket for PCIe location |
Intel VROC RAID Key for NVMe | AOC-VROCINTMOD | 1 | Intel SSD Only Upgrade module; RAID 0/1/10/5 |
AOC-VROCSTNMOD | 1 | Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10 | |
AOC-VROCPREMOD | 1 | Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5 | |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
TPM | AOM-TPM-9670V-S-O | 1 | TPM 2.0, vertical form factor, provisioned for server |
AOM-TPM-9671V-S-O | 1 | TPM 1.2, vertical form factor, provisioned for server |
Part Number | MBD-X12SPI-TF | CSE-826BTS-R802LPB |
Qty | 1 | 1 |
Description | Super X12SPI-TF Motherboard | 2U Chassis |
Part Number | AOC-S3916L-H16IR-32DD-P |
Qty | 1 |
Description | 16 int 12Gb/s ports, x8 Gen4, ROC - LP, 32HDDw/exp,RoHS |
Part Number | BPN-SAS3-LA26A-N12 |
Qty | 1 |
Description | 2U 12-Slot LFF Backplane Supports 12 x SAS3/SATA3/NVMe4 Stor |
Part Number | CBL-CDAT-0728 | CBL-SAST-1249-100 | CBL-SAST-1281-100 | CBL-CDAT-0921-85 | CBL-PWCD-0160-IS | CBL-PWEX-1069 |
Qty | 1 | 1 | 1 | 1 | 2 | 3 |
Description | 4 Pin to 4 Pin I2C Cable, 65cm, 26AWG, 4 Wires, Pinout 1-1 | Slimline x8 (STR) to 2x Slimline x4 (STR),50CM,100 OHM, | Slimline x8 (STR) to 2x Slimline x4 (STR),80CM,100 OHM, | I2C,(1x4F to 1x4F)/P2.5,85CM,26AWG,RoHS | PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH | PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,30CM,22AWG,5A/pin,RoHS |
Part Number | MCP-260-00042-1N |
Qty | 1 |
Description | Standard I/O Shield for X12SPi with EMI Gasket |
Part Number | MNL-2361-QRG |
Qty | 1 |
Description | 520P-ACTR12L/H Quick Reference Guide |
Part Number | SFT-OOB-LIC |
Qty | 1 |
Description | License key for enabling OOB BIOS management |
Part Number | SNK-P0078P |
Qty | 1 |
Description | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
Part Number | PWS-802A-1R |
Qty | 2 |
Description | 1U 800W 100-240Vac/47-63Hz, and DC240 input |
Part Number | PDB-PT826-8824 |
Qty | 1 |
Description | PDB with longer 24pin for SC826B |
Part Number | FPB-TB826-T |
Qty | 1 |
Description | Chassis transfer board for SC826 |
Part Number | MCP-220-00075-0B |
Qty | 12 |
Description | Black gen 5.5 hot-swap 3.5" HDD tray |
Part Number | MCP-240-82608-0N |
Qty | 1 |
Description | 216B/826B LP rear window,RoHS/REACH,PBF |
Part Number | MCP-290-00053-0N | MCP-290-00060-0N |
Qty | 1 | 1 |
Description | Rail set, quick/quick, default for 2,3U 17.2"W | Threaded rail adapter default for round hole rack |
Part Number | MCP-310-29001-0N |
Qty | 1 |
Description | SC825/826/216/213 Intel DP X9,X8 air shroud 13.68x13/12x13 |
Part Number | FAN-0166L4 OR | FAN-0206L4 |
Qty | 3 | - |
Description | 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4) | 80x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers |
Part Number | MCP-220-82619-0N + 1x CBL-SAST-1264-85 |
Qty | 1 |
Description | Rear hot-swap 2x 2.5" NVMe drive kit |
Part Number | MCP-220-82616-0N |
Qty | 1 |
Description | Rear hot-swap 2x 2.5" SATA/SAS drive kit |
Part Number | MCP-220-00043-0N |
Qty | - |
Description | Hot-swap Gen-4 3.5" to 2.5" HDD tray, Black |
Part Number | BTR-CVPM05 & MCP-240-00203-0N (For S3916) |
Qty | 1 |
Description | CacheVault for Broadcom 3916 with SuperCap mounting bracket for PCIe location |
Part Number | AOC-VROCINTMOD | AOC-VROCSTNMOD | AOC-VROCPREMOD |
Qty | 1 | 1 | 1 |
Description | Intel SSD Only Upgrade module; RAID 0/1/10/5 | Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10 | Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5 |
Part Number | SFT-DCMS-Single |
Qty | 1 |
Description | DataCenter Management Package (per node license) |
Part Number | AOM-TPM-9670V-S-O | AOM-TPM-9671V-S-O |
Qty | 1 | 1 |
Description | TPM 2.0, vertical form factor, provisioned for server | TPM 1.2, vertical form factor, provisioned for server |