Certain products may not be available in your region
Key Applications
Key Features
...
...
|
|
|
Supermicro’s JumpStart program offers convenient remote access to fully-configured systems with SSH, VNC, and web IPMI, featuring the latest CPUs and GPUs. Schedule free access to validate, test, and benchmark your own workloads on Supermicro’s top-end server platforms with a few simple steps.
Schedule AccessOptional Parts List | |||
Part Number | Qty | Description | |
3108 CacheVault | BTR-TFM8G-LSICVM02 | 1 | CacheVault for Broadcom 3108 (requires a mount) |
3108 RAID Card | AOC-S3108L-H8IR-16DD | 1 | Standard LP 8 internal ports (12Gb/s) Gen-3 16HDD RAID 0, 1, 5, 6, 10, 50, 60 |
CBL-SAST-1260-100 | 1 | MiniSAS HD x8 (LE) to 2x Slimline x4 (STR) 60CM | |
3808 HBA Card | AOC-S3808L-L8IT | 1 | Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
3816 HBA Card | AOC-S3816L-L16IT | 1 | Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA |
CBL-SAST-1265F-100 | 1 | Slimline x8 (STR) to Slimline x4 (STR) 64CM | |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
3908 RAID Card | CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
AOC-S3908L-H8IR-16DD | 1 | Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60 | |
3908/3916 CacheVault | BTR-CVPM05 | 1 | CacheVault for Broadcom 3908/3916 (requires a mount) |
3916 RAID Card | AOC-S3916L-H16IR-32DD | 1 | Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60 |
CBL-SAST-1265F-100 | 1 | Slimline x8 (STR) to Slimline x4 (STR) 64CM | |
CBL-SAST-1276F-100 | 1 | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | |
AIOM Network Card(s) | AOC-AG-i2M | - | OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2 |
AOC-A25G-i4SM | - | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 | |
AOC-A25G-m2SM | - | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX | |
AOC-ATG-i2T2SM | - | OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4 | |
AOC-A25G-i2SM | - | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 | |
AOC-A25G-b2SM | - | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2 | |
AOC-A100G-b2CM | - | OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508 | |
AOC-AG-i4M | - | OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4 | |
AOC-AG-i4SM | - | OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4 | |
AOC-AH25G-m2S2TM | - | OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2 | |
AOC-ATG-b2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416 | |
AOC-ATG-i2SM | - | OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2 | |
AOC-ATG-i2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2 | |
AOC-ATG-i4SM | - | OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1 | |
AOC-ATGC-i2TM | - | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2 | |
Cable Management Arm | MCP-290-00073-0N | 1 | Supermicro Cable Management Arm for 2U, 3U and 4U chassis |
MCP-120-82601-0N | 1 | Cable Arm Adapter for 2U | |
CacheVault Mount | MCP-240-00203-0N | 1 | CacheVault mounting bracket for PCIe slot |
MCP-240-00127-0N | 1 | CacheVault mounting tray for 2.5" drive bay | |
MCP-240-21747-0N | 1 | CacheVault mounting card for AIOM slot | |
Dummy Cover | CSE-PT0130L | 1 | Power Supply Dummy Cover |
GPU Power Cable | CBL-PWEX-1040 | 2 | PWYCB GPU 2x4M/CPU to two (2x3F+2x1F)/PCIe P4.2 5CM |
GPU RAID | SFT-GRD-SRBUN1010SW | 1 | GRAID RAID License for A2000 GPU 32 NVMe |
GPU-NVQRTX-A2000 | 1 | NVIDIA PNY Quadro RTX A2000 6 GB GDDR6 PCIe 4.0 | |
GPU Support (FL) | SNK-P0077V | 2 | X12 ICX/CPX CPU Heatsink VC Base |
MCP-310-82613-0N | 1 | Plastic Air Shroud for GPU | |
GPU Support (LP) | SNK-P0078PC | 2 | 2U Passive CPU Heat Sink w/ a Side Air Channel for X12 Generation Intel Whitley and Cedar Island Platforms |
MCP-310-82614-0B | 1 | Dummy GPU | |
License | SFT-SDDC-SINGLE | 1 | Supermicro Data Center Monitor License |
SFT-DCMS-SINGLE •![]() |
1 | Supermicro System Managment Software License | |
Low Power Fan | FAN-0181L4 | 3 | 80x80x38 mm 9.4K RPM Chassis Middle Fan |
M.2 Tray | AOC-SLG3-2SM2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 SATA Modules RAID 0,1 |
AOC-SLG4-2H8M2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0,1 | |
AOC-SLG3-2M2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules | |
AOC-SLG3-2NM2 | - | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules RAID 0,1 | |
NC-SI Cable | CBL-PWEX-1099-34 | 1 | FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM |
NVMe Cable | CBL-KIT-620C-TN12R-12 | 1 | Enables 12 NVMe drive bays. Kit includes: 4x CBL-SAST-1236LP-85 (bay # 2-5, 8-11) 2x CBL-SAST-1267FLP-85 (bay # 0-1,6-7) |
Power Supply | PWS-1K11P-1R | 2 | DC 48V Input 1010W Power Supply |
PWS-1K23A-1R | 2 | (Default) AC-DC 1200W Titanium Level Power Supply | |
PWS-1K68A-1R | 2 | AC-DC 1600W Titanium Level Power Supply | |
Rear NVMe Drive Kit | CBL-KIT-620C-TN12R-14 | 1 | For 12+2 NVMe configuration. Kit includes: 3x CBL-SAST-1236LP-85 (bay # 4-7, 12-13) 4x CBL-SAST-1267FLP-85 (bay # 0-3, 8-11) |
MCP-220-82620-0N | 1 | Rear Window Module for 2x 2.5" NVMe Drives PCIE Gen 4 | |
CBL-SAST-1236LP-85 | 1 | 2 Rear NVMe only. Slimline x8 (STR) to 2x SlimlineLP x4 (STR) 40/40CM | |
CBL-PWEX-1276 | 1 | 1x4M/P5.08 to 2x2Micro-Fit Male 15cm | |
Rear SATA Drive Kit | MCP-220-82616-0N | 1 | Rear Window Module for 2x 2.5" SATA/SAS Drives |
Riser Upgrade | CBL-SAST-1296LP-85 | 3 | 2*SlimSASLP x4 (STR) to SlimSASLP x8 (STR) 55CM 85ohm |
CBL-SAST-1296LPA-85 | 1 | 2*SlimSASLP x4 (STR) to SlimSASLP x8 (STR) 55CM 85ohm LNRV | |
RSC-D2-666G4 | 1 | 2U LHS DCO Riser card with three PCIe 4.0x16slots | |
RSC-D2R-666G4 | 1 | 2U RHS DCO Riser card with three PCIe 4.0 x16slots | |
TPM | AOM-TPM-9672V-FIPS | 1 | SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor |
AOM-TPM-9672V | 1 | SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor | |
AOM-TPM-9670V-S-FIPS | 1 | SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor | |
AOM-TPM-9670V | 1 | SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor | |
VROC HW Key | AOC-VROCPREMOD | 1 | Intel VROC Premium RAID 0, 1, 5, 10 |
AOC-VROCSTNMOD | 1 | Intel VROC Standard RAID 0, 1, 10 |
Part Number | BTR-TFM8G-LSICVM02 |
Qty | 1 |
Description | CacheVault for Broadcom 3108 (requires a mount) |
Part Number | AOC-S3108L-H8IR-16DD | CBL-SAST-1260-100 |
Qty | 1 | 1 |
Description | Standard LP 8 internal ports (12Gb/s) Gen-3 16HDD RAID 0, 1, 5, 6, 10, 50, 60 | MiniSAS HD x8 (LE) to 2x Slimline x4 (STR) 60CM |
Part Number | AOC-S3808L-L8IT | CBL-SAST-1276F-100 |
Qty | 1 | 1 |
Description | Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | AOC-S3816L-L16IT | CBL-SAST-1265F-100 | CBL-SAST-1276F-100 |
Qty | 1 | 1 | 1 |
Description | Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA | Slimline x8 (STR) to Slimline x4 (STR) 64CM | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | CBL-SAST-1276F-100 | AOC-S3908L-H8IR-16DD |
Qty | 1 | 1 |
Description | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 | Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60 |
Part Number | BTR-CVPM05 |
Qty | 1 |
Description | CacheVault for Broadcom 3908/3916 (requires a mount) |
Part Number | AOC-S3916L-H16IR-32DD | CBL-SAST-1265F-100 | CBL-SAST-1276F-100 |
Qty | 1 | 1 | 1 |
Description | Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60 | Slimline x8 (STR) to Slimline x4 (STR) 64CM | Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100 |
Part Number | AOC-AG-i2M | AOC-A25G-i4SM | AOC-A25G-m2SM | AOC-ATG-i2T2SM | AOC-A25G-i2SM | AOC-A25G-b2SM | AOC-A100G-b2CM | AOC-AG-i4M | AOC-AG-i4SM | AOC-AH25G-m2S2TM | AOC-ATG-b2TM | AOC-ATG-i2SM | AOC-ATG-i2TM | AOC-ATG-i4SM | AOC-ATGC-i2TM |
Qty | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Description | OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2 | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX | OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4 | OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1 | OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2 | OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508 | OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4 | OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4 | OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2 | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416 | OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2 | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2 | OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1 | OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2 |
Part Number | MCP-290-00073-0N | MCP-120-82601-0N |
Qty | 1 | 1 |
Description | Supermicro Cable Management Arm for 2U, 3U and 4U chassis | Cable Arm Adapter for 2U |
Part Number | MCP-240-00203-0N | MCP-240-00127-0N | MCP-240-21747-0N |
Qty | 1 | 1 | 1 |
Description | CacheVault mounting bracket for PCIe slot | CacheVault mounting tray for 2.5" drive bay | CacheVault mounting card for AIOM slot |
Part Number | CSE-PT0130L |
Qty | 1 |
Description | Power Supply Dummy Cover |
Part Number | CBL-PWEX-1040 |
Qty | 2 |
Description | PWYCB GPU 2x4M/CPU to two (2x3F+2x1F)/PCIe P4.2 5CM |
Part Number | SFT-GRD-SRBUN1010SW | GPU-NVQRTX-A2000 |
Qty | 1 | 1 |
Description | GRAID RAID License for A2000 GPU 32 NVMe | NVIDIA PNY Quadro RTX A2000 6 GB GDDR6 PCIe 4.0 |
Part Number | SNK-P0077V | MCP-310-82613-0N |
Qty | 2 | 1 |
Description | X12 ICX/CPX CPU Heatsink VC Base | Plastic Air Shroud for GPU |
Part Number | SNK-P0078PC | MCP-310-82614-0B |
Qty | 2 | 1 |
Description | 2U Passive CPU Heat Sink w/ a Side Air Channel for X12 Generation Intel Whitley and Cedar Island Platforms | Dummy GPU |
Part Number | SFT-SDDC-SINGLE | SFT-DCMS-SINGLE •![]() |
Qty | 1 | 1 |
Description | Supermicro Data Center Monitor License | Supermicro System Managment Software License |
Part Number | FAN-0181L4 |
Qty | 3 |
Description | 80x80x38 mm 9.4K RPM Chassis Middle Fan |
Part Number | AOC-SLG3-2SM2 | AOC-SLG4-2H8M2 | AOC-SLG3-2M2 | AOC-SLG3-2NM2 |
Qty | - | - | - | - |
Description | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 SATA Modules RAID 0,1 | Low Profile PCIe x8 add-on card supports 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0,1 | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules | Low Profile PCIe x8 add-on card supports 2 PCIe 3.0 x4 M-Key M.2 NVMe Modules RAID 0,1 |
Part Number | CBL-PWEX-1099-34 |
Qty | 1 |
Description | FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM |
Part Number | CBL-KIT-620C-TN12R-12 |
Qty | 1 |
Description | Enables 12 NVMe drive bays. Kit includes: ,4x CBL-SAST-1236LP-85 (bay # 2-5, 8-11) ,2x CBL-SAST-1267FLP-85 (bay # 0-1,6-7) |
Part Number | PWS-1K11P-1R | PWS-1K23A-1R | PWS-1K68A-1R |
Qty | 2 | 2 | 2 |
Description | DC 48V Input 1010W Power Supply | (Default) AC-DC 1200W Titanium Level Power Supply | AC-DC 1600W Titanium Level Power Supply |
Part Number | CBL-KIT-620C-TN12R-14 | MCP-220-82620-0N | CBL-SAST-1236LP-85 | CBL-PWEX-1276 |
Qty | 1 | 1 | 1 | 1 |
Description | For 12+2 NVMe configuration. Kit includes: ,3x CBL-SAST-1236LP-85 (bay # 4-7, 12-13) ,4x CBL-SAST-1267FLP-85 (bay # 0-3, 8-11) | Rear Window Module for 2x 2.5" NVMe Drives PCIE Gen 4 | 2 Rear NVMe only. Slimline x8 (STR) to 2x SlimlineLP x4 (STR) 40/40CM | 1x4M/P5.08 to 2x2Micro-Fit Male 15cm |
Part Number | MCP-220-82616-0N |
Qty | 1 |
Description | Rear Window Module for 2x 2.5" SATA/SAS Drives |
Part Number | CBL-SAST-1296LP-85 | CBL-SAST-1296LPA-85 | RSC-D2-666G4 | RSC-D2R-666G4 |
Qty | 3 | 1 | 1 | 1 |
Description | 2*SlimSASLP x4 (STR) to SlimSASLP x8 (STR) 55CM 85ohm | 2*SlimSASLP x4 (STR) to SlimSASLP x8 (STR) 55CM 85ohm LNRV | 2U LHS DCO Riser card with three PCIe 4.0x16slots | 2U RHS DCO Riser card with three PCIe 4.0 x16slots |
Part Number | AOM-TPM-9672V-FIPS | AOM-TPM-9672V | AOM-TPM-9670V-S-FIPS | AOM-TPM-9670V |
Qty | 1 | 1 | 1 | 1 |
Description | SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor | SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor | SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor | SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor |
Part Number | AOC-VROCPREMOD | AOC-VROCSTNMOD |
Qty | 1 | 1 |
Description | Intel VROC Premium RAID 0, 1, 5, 10 | Intel VROC Standard RAID 0, 1, 10 |