SuperServer SYS-211E-FRN2T

DatasheetShare IconShare

X13 2U Short-depth front I/O System with 2 x 10G ports, 2x 2.5" NVMe drive bays and redundant AC PSU

Integrated Board: X13SEM-TF
Learn more

Key Applications

  • 5G Core and Edge
  • AI Inference and Machine Learning
  • Network Function Virtualization
  • Cloud Computing

Key Features

  1. Design with compliance to NEBS-Level 3
  2. Single Socket E (LGA-4677) 5th/4th Gen Intel® Xeon® Scalable processors
  3. 8 DIMM slots; Up to 2TB 3DS ECC DDR5-5600; R-DIMM/R-DIMM 3DS
  4. Up to 3 PCIe 5.0 x16 FHHL, 1 PCIe 5.0 X16 HHHL & 1 PCIe 5.0 x8 FHHL expansion slots for Accelerator Add-On-Cards
    Up to 6 Configurable PCIe 5.0 slots (4 standard + 2 optional)
  5. Onboard 2x 10GbE ports
  6. 2x 2.5" NVMe drive bays
  7. Redundant 800W AC Power Supplies
  8. Ultra short depth, 2U Front I/O Edge Server
...
...
SYS-211E-FRN2T
Specifications Parts List
Specifications
Product SKUs
SuperServer SYS-211E-FRN2T
Motherboard
Super X13SEM-TF
Processor
CPU
Core Count
  • Up to 60C/120T; Up to 112.5MB Cache
Note
  • Supports up to 350W TDP CPUs (Air Cooled)*
  • *Air Cooled CPUs with TDP over 205W only supported under specific conditions. Contact a Supermicro representative for details.
GPU
Max GPU Count
  • Up to 3 single-width GPUs
Supported GPU
CPU-GPU Interconnect
  • PCIe 5.0 x16 CPU-to-GPU Interconnect
GPU-GPU Interconnect
  • PCIe
System Memory
Memory
  • Slot Count: 8 DIMM slots
  • Max Memory (2DPC): Up to 2TB 5600MT/s ECC DDR5 RDIMM
  • View Memory Options
Memory Voltage
  • 1.1V
On-Board Devices
NVMe
Chipset
  • Intel® C741
Network Connectivity
  • 2 QSFP28 25GbE with Intel® XXV710 (optional)
  • 2 QSFP+ 40GbE with Intel® X710-BM2 (optional)
  • 4 RJ45 1GbE with Intel® I350 (optional)
  • 2 QSFP28 100GbE with Intel® E810-CAM2 (optional)
  • 2 RJ45 10GBASE-T with Intel® X550
  • 2 SFP+ 10GbE with Intel® X710-BM2 (optional)
  • 2 QSFP56 100GbE (optional)
  • 4 QSFP28 25GbE with Intel® E810-CAM1 (optional)
  • 2 QSFP56 200GbE (optional)
  • View AOC Options
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated BMC LAN port
  • 2 RJ45 10 GbE LAN ports (Intel® X550-AT2)
USB
  • 2 USB 2.0 ports(front)
  • 2 USB 3.2 Gen1 ports(front)
Video
  • 1 VGA port
Serial
  • 1 port
System BIOS
BIOS Type
  • AMI 256MB SPI Flash
Management
Software
Power configurations
  • ACPI Power Management
  • Power-on mode for DC power recovery
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • Supply Chain Security: Remote Attestation
  • Runtime BMC Protections
  • System Lockdown
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • CPU thermal trip support, PEPI
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-211M
Dimensions and Weight
Height
  • 3.5" (88.9 mm)
Width
  • 17.2" (436.88 mm)
Depth
  • 11.8" (298.8 mm)
Package
  • 7.4" (H) x 19.3" (W) x 23.3" (D)
Weight
  • Gross Weight: 22 lbs (10 kg)
  • Net Weight: 17 lbs (7.7 kg)
Available Color
  • Silver/Black
Front Panel
LED
  • HDD activity
  • LAN1 activity
  • LAN2 activity
  • Power status
  • System information
Buttons
  • Power On/Off 
  • UID button
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 2 PCIe 5.0 x16 FHHL slots
    • 1 PCIe 5.0 x16 HHHL slot
    • 1 PCIe 5.0 x8 HHHL slot
  • Option A*
    • 3 PCIe 5.0 x16 FHHL slots
    • 1 PCIe 5.0 x16 HHHL slot
    • 1 PCIe 5.0 x8 FHHL slot
  • Option B*
    • 3 PCIe 5.0 x16 FHHL slots
    • 2 PCIe 5.0 x8 HHHL slots
    • 1 PCIe 5.0 x8 HHHL slot
  • ...
  • View AOC Options
Drive Bays / Storage
Drive Bays Configuration
M.2
System Cooling
Fans
  • 4x 4-PIN PWM 8cm Fan(s)
Air Shroud
  • 1 Air Shroud
Power Supply
Operating Environment
Environmental Spec.
  • Operating Temperature: 0°C to 45°C (32°F to 113°F)
  • Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity: 8% to 90% (non-condensing)
  • Non-operating Relative Humidity: 5% to 95% (non-condensing)
Environmental / Recycling
Recycle
Resources & Downloads
Parts List
Standard Parts (Parts Included)
Part Number Qty Description
Motherboard / Chassis MBD-X13SEM-TF

CSE-211M
1

1
Super X13SEM-TF Motherboard

2U Chassis
Backplane BPN-NVME5-826N-B2B 1 2-Port PCIe Gen 5 U.2 NVMe SSD Storage Backplane
Cable CBL-MCIO-1230M5 1 MCIO x8 (STR to STR),30CM,85OHM,RoHS
CBL-PCBA-G5T16-0809 1 2 PCIe Gen5 x16+pwr 08/09cm,30AWG,85 Ohm,RoHS
CBL-PWCD-0160-IS 2 PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
CBL-MCIO-1218M5 OR 1 MCIO x8 (STR to STR),18CM,85OHM,RoHS
CBL-MCIO-1218M5-1 MCIO x8 (STR to STR),18CM,85OHM,RoHS
CBL-MCIO-1218M5R OR 1 MCIO (x8 STR to x8 RA),18CM,85OHM,RoHS
CBL-MCIO-1218M5R-1 MCIO x8 (STR to RA),18CM,85OHM,RoHS
CBL-MCIO-1230M5R OR 1 MCIO x8 (STR to RA),30CM,85OHM,RoHS
CBL-MCIO-1230M5R-1 MCIO x8 (STR to RA),30CM,85OHM,RoHS
CBL-CDAT-1058 1 NCSI 2x8 to 2x8, Ph2.54, 60cm shielded,28AWG, RoHS,RoHS
Drive Tray(s) MCP-220-00167-0B 2 Gen 3 2.5-inch Tool-less NVMe drive tray (clip design),RoHS
MCP-220-00147-0B 2 Black gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design)
Parts MCP-260-21102-0B 1 1U height IO shield for X13SEM-F/TF MBD, with gasket, bl
Air Shroud MCP-310-21105-0B 1 Mylar air shroud for 211M w/ X13SEM-TF
Manual MNL-2519-QRG 1 211E-FRDN2T/FRN2T Quick Reference Guide
Power Distributor PDB-PT211M-3424 1 2U support redundancy powers up to 800W for SC211M with 2 Mi
Power Supply PWS-804S-1R 2 800W 100-240Vac input, Platinum, base module PWS-804P-1R
Riser Card RSC-S-68G5 1 1U LHS Standard riser card with one PCIe 5.0X16andonePC
Software SFT-OOB-LIC 1 License key for enabling OOB BIOS management
Heatsink / Retention SNK-P0088P 1 2U Passive CPU HS for X13 EGS and X14-SP BHS-SP Systems
*Fan FAN-0220L4 4 80x80x38 mm, 14.9K RPM Exhaust Fan for SYS-120P-FRDN6T Serve
*Front Panel FPB-TB826 1 16 pin Cable Adaptor Board for SC826
*Rail Set MCP-290-21106-0N 1 1U height sliding rail for SC211M chassis
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Standard Parts (Parts Included)
Motherboard / Chassis
Part NumberMBD-X13SEM-TF CSE-211M
Qty1 1
DescriptionSuper X13SEM-TF Motherboard 2U Chassis
Backplane
Part NumberBPN-NVME5-826N-B2B
Qty1
Description2-Port PCIe Gen 5 U.2 NVMe SSD Storage Backplane
Cable
Part NumberCBL-MCIO-1230M5CBL-PCBA-G5T16-0809CBL-PWCD-0160-ISCBL-MCIO-1218M5 OR CBL-MCIO-1218M5-1CBL-MCIO-1218M5R OR CBL-MCIO-1218M5R-1CBL-MCIO-1230M5R OR CBL-MCIO-1230M5R-1CBL-CDAT-1058
Qty1121-1-1-1
DescriptionMCIO x8 (STR to STR),30CM,85OHM,RoHS2 PCIe Gen5 x16+pwr 08/09cm,30AWG,85 Ohm,RoHSPWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACHMCIO x8 (STR to STR),18CM,85OHM,RoHSMCIO x8 (STR to STR),18CM,85OHM,RoHSMCIO (x8 STR to x8 RA),18CM,85OHM,RoHSMCIO x8 (STR to RA),18CM,85OHM,RoHSMCIO x8 (STR to RA),30CM,85OHM,RoHSMCIO x8 (STR to RA),30CM,85OHM,RoHSNCSI 2x8 to 2x8, Ph2.54, 60cm shielded,28AWG, RoHS,RoHS
Drive Tray(s)
Part NumberMCP-220-00167-0BMCP-220-00147-0B
Qty22
DescriptionGen 3 2.5-inch Tool-less NVMe drive tray (clip design),RoHSBlack gen-3 hot-swap 2.5"; Tool-less HDD tray (clip design)
Parts
Part NumberMCP-260-21102-0B
Qty1
Description1U height IO shield for X13SEM-F/TF MBD, with gasket, bl
Air Shroud
Part NumberMCP-310-21105-0B
Qty1
DescriptionMylar air shroud for 211M w/ X13SEM-TF
Manual
Part NumberMNL-2519-QRG
Qty1
Description211E-FRDN2T/FRN2T Quick Reference Guide
Power Distributor
Part NumberPDB-PT211M-3424
Qty1
Description2U support redundancy powers up to 800W for SC211M with 2 Mi
Power Supply
Part NumberPWS-804S-1R
Qty2
Description800W 100-240Vac input, Platinum, base module PWS-804P-1R
Riser Card
Part NumberRSC-S-68G5
Qty1
Description1U LHS Standard riser card with one PCIe 5.0X16andonePC
Software
Part NumberSFT-OOB-LIC
Qty1
DescriptionLicense key for enabling OOB BIOS management
Heatsink / Retention
Part NumberSNK-P0088P
Qty1
Description2U Passive CPU HS for X13 EGS and X14-SP BHS-SP Systems
*Fan
Part NumberFAN-0220L4
Qty4
Description80x80x38 mm, 14.9K RPM Exhaust Fan for SYS-120P-FRDN6T Serve
*Front Panel
Part NumberFPB-TB826
Qty1
Description16 pin Cable Adaptor Board for SC826
*Rail Set
Part NumberMCP-290-21106-0N
Qty1
Description1U height sliding rail for SC211M chassis
Notes:
  1. Parts with * are inside the chassis
  2. Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.

IoT SuperServer SYS-211E-FRN2T

Certain products may not be available in your region