Question
How is CMM redundancy maintained on a Microblade chassis with two CMM?
Answer
There is a Master and Slave relationship between two CMM in a chassis. If for some reason the Master CMM goes down, the Slave CMM will become active. When the Master CMM obtains an IP from the DHCP server, the slave CMM will sync and store the IP. If the Master CMM goes down, the Slave CMM will be active with the same IP. By the time the management station submits ARP, the Slave CMM MAC will be updated. CMM management will continue.
Was this FAQ helpful?
YES      NO

Enter Comments Below:
Note: Your comments/feedback should be limited to this FAQ only. For technical support, please send an email to support@supermicro.com.



 Enter your email address below if you'd like technical support staff to reply:


 Please type the Captcha (no space)
4 9 F D