SuperServer SYS-621C-TN12R (Complete System Only)

2U DP CloudDC with 12 hot-swap 3.5" NVMe/SAS/SATA bays and 4 PCIe 5.0 x16 slots + 2 PCIe 5.0 x16 AIOM slots

Key Applications

  • Web Server, Firewall Application
  • Data Center Optimized, Value IaaS
  • Cloud Computing, Compact Server
  • DNS & Gateway Servers, Firewall Application
  • CDN, Edge Nodes

Key Features

  1. Dual sockets E (LGA-4677) 5th and 4th Gen Intel®  Xeon® Scalable processors
  2. 16 DIMMs up to 4TB 3DS ECC DDR5-5600: RDIMM
  3. 4 PCIe 5.0 x8 FHHL (optional: combine into 2 PCIe 5.0 x16);
    2 PCIe 5.0 x16 FHHL;
    2 PCIe 5.0 x4 NVMe M.2
  4. Dual AIOM (OCP 3.0) slots with NCSI for networking, 1 dedicated IPMI LAN
  5. 12x 3.5/2.5" hot-swap hybrid NVMe/SATA/SAS drive bays
  6. 3 heavy duty fans with optimal fan speed control, 1 air shroud
  7. 1200W redundant Titanium level 100-240Vac and 200-240 Vdc power supplies
  8. 1 VGA, 1 COM, 2 USB 3.0 (rear)
...
...
SYS-621C-TN12R
Specifications Resources & Downloads Parts List
Specifications
Product SKUs
SuperServer SYS-621C-TN12R
Motherboard
Super X13DDW-A
Processor
CPU
Core Count
  • Up to 64C/128T; Up to 112.5MB Cache per CPU
Note
  • Supports up to 350W TDP CPUs (Air Cooled)*
  • *Air Cooled CPUs with TDP over 270W only supported under specific conditions. Contact a Supermicro representative for details.
GPU
Max GPU Count
  • Up to 2 double-width or 6 single-width GPUs
Supported GPU
  • NVIDIA PCIe: H100 NVL, H100, L40, RTX A6000, RTX A5000, RTX A4500, RTX A4000, L40S, L4, A2
  • Intel PCIe: Intel Data Center GPU Flex 140, Intel Data Center GPU Flex 170
  • View GPU Options
System Memory
Memory
  • Slot Count: 16 DIMM slots
  • Max Memory (1DPC): Up to 4TB 5600MT/s ECC DDR5 RDIMM
  • View Memory Options
Memory Voltage
  • 1.1V
On-Board Devices
SATA
  • SATA (6Gbps) ; RAID 0/1/5/10 support
NVMe
Chipset
  • Intel® C741
Network Connectivity
Input / Output
LAN
  • 1 RJ45 1 GbE Dedicated BMC LAN port
USB
  • 2 USB 3.0 ports(rear)
Video
  • 1 VGA port
Serial
  • 1 COM port(Rear)
TPM
  • 1 TPM header
System BIOS
BIOS Type
  • AMI 32MB SPI FLASH ROM
Management
Software
Power configurations
  • ACPI/APM Power Management
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
  • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
Features
  • Cryptographically Signed Firmware
  • Secure Boot
  • Secure Firmware Updates
  • Automatic Firmware Recovery
  • Supply Chain Security: Remote Attestation
  • Runtime BMC Protections
  • System Lockdown
PC Health Monitoring
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 8 Phase-switching voltage regulator
Chassis
Form Factor
  • 2U Rackmount
Model
  • CSE-LA26TS-R1K23AWP1
Dimensions and Weight
Height
  • 3.5" (89 mm)
Width
  • 17.2" (437 mm)
Depth
  • 25.5" (648 mm)
Package
  • 11.4" (H) x 26.7" (W) x 34.5" (D)
Weight
  • Gross Weight: 59 lbs (26.76 kg)
  • Net Weight: 33 lbs (15 kg)
Available Color
  • Black front & sliver body
Front Panel
LED
  • Drive activity
  • Network activity
  • Power status
  • Universal Information (UID)
Buttons
  • Power On/Off
  • Universal Information (UID)
Expansion Slots
PCI-Express (PCIe) Configuration
  • Default
    • 4 PCIe 5.0 x8 (in x16) FHFL double-width slots
    • 2 PCIe 5.0 x16 FHHL slots
    • 2 PCIe 5.0 x16 AIOM slots (OCP 3.0 compatible)
  • Option A
    • 2 PCIe 5.0 x16 FHFL double-width slots
    • 2 PCIe 5.0 x16 FHHL slots
    • 2 PCIe 5.0 x16 AIOM slots (OCP 3.0 compatible)
  • Option B
    • 4 PCIe 5.0 x16 FHFL double-width slots
    • 2 PCIe 5.0 x16 FHHL slots
    • 2 PCIe 5.0 x16 AIOM slots (OCP 3.0 compatible)
  • View AOC Options
CXL Support
  • Up to 2 CXL 1.1 x16/x8 Type 2/Type 3 devices
Drive Bays / Storage
Drive Bays Configuration
  • Default: Total 12 bays
    • 12 front hot-swap 3.5" NVMe*/SAS*/SATA* drive bays
  • Option A: Total 12 bays
    • 12 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays
  • (*NVMe/SAS/SATA support may require additional storage controller and/or cables, please see the optional parts list for details)
  • View NVMe Options
  • View Drive Options
M.2
  • 2 M.2 PCIe 5.0 x4 NVMe slots (M-key 2280(default); VROC required for RAID)
  • View M.2 Options
System Cooling
Fans
  • 3x 8cm heavy duty fans with optimal fan speed control
Air Shroud
  • 1 Air Shroud
Power Supply
Operating Environment
ROHS
  • RoHS Compliant
Environmental Spec.
  • Name: A2
  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: -30°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 8% to 80% (max 21° DP; non-condensing)
  • Non-operating Relative Humidity: 8% to 90% (max 38° DP; non-condensing)
Resources & Downloads
Parts List
Optional Parts List
Part Number Qty Description
3808 HBA Card AOC-S3808L-L8IT 1 Standard LP 8 internal ports (12Gb/s) Gen-4 16HDD HBA
CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
3816 HBA Card AOC-S3816L-L16IT 1 Standard LP 16 internal ports (12Gb/s) Gen-4 122HDD HBA
CBL-SAST-1265F-100 1 Slimline x8 (STR) to Slimline x4 (STR) 64CM
CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
3908 RAID Card AOC-S3908L-H8IR-16DD 1 Standard LP 8 internal ports (12Gb/s) Gen-4 122HDD RAID 0, 1, 5, 6, 10, 50, 60
CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
3908/3916 CacheVault BTR-CVPM05 1 CacheVault for Broadcom 3908/3916 (requires a mount)
3916 RAID Card AOC-S3916L-H16IR-32DD 1 Standard LP 16 internal ports (12Gb/s) Gen-4, 32HDD RAID 0, 1, 5, 6, 10, 50, 60
CBL-SAST-1265F-100 1 Slimline x8 (STR) to Slimline x4 (STR) 64CM
CBL-SAST-1276F-100 1 Slimline x8 (LE) to 2x Slimline x4 (STR) 76/76CM, alternative: CBL-SAST-1264F-100
AIOM Network Card(s) AOC-AH25G-m2S2TM - OCP 3.0 AIOM 2x 25GbE SFP28 & 2x 10GbE RJ45 PCIe x8/x4 Mellanox® CX4 Lx EN & Intel® X550-AT2
AOC-A25G-i4SM - OCP 3.0 AIOM 4x 25GbE SFP28 PCIe x8 Intel® E810-CAM1
AOC-AG-i4SM - OCP 3.0 AIOM 4x 1GbE SFP PCIe 2.1 x4 Intel® i350-AM4
AOC-AG-i4M - OCP 3.0 AIOM 4x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM4
AOC-AG-i2M - OCP 3.0 AIOM 2x 1GbE RJ45 PCIe 2.1 x4 Intel® i350-AM2
AOC-A25G-m2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Mellanox® CX-6 LX
AOC-A100G-b2CM - OCP 3.0 AIOM 2x 100GbE QSFP28 PCIe 4.0 x16 Broadcom® BCM57508
AOC-A25G-b2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Broadcom® BCM57414
AOC-A25G-i2SM - OCP 3.0 AIOM 2x 25GbE SFP28 PCIe x8 Intel® E810-XXVAM2
AOC-ATG-b2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Broadcom® BCM57416
AOC-ATG-i2SM - OCP 3.0 AIOM 2x 10GbE SFP+ PCIe 3.0 x8 Intel® X710-BM2
AOC-ATG-i2T2SM - OCP 3.0 AIOM 4x 10GbE RJ45 & SFP+ PCIe x8 Intel® X710-TM4
AOC-ATG-i2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X550-AT2
AOC-ATG-i4SM - OCP 3.0 AIOM 4x 10GbE SFP+ PCIe 3.0 x8 Intel® XL710-BM1
AOC-ATGC-i2TM - OCP 3.0 AIOM 2x 10GbE RJ45 PCIe 3.0 x4 Intel® X710-AT2
Cable Management Arm MCP-120-82601-0N 1 Cable Arm Adapter
MCP-290-00073-0N 1 Supermicro Cable Management Arm for 2U, 3U and 4U chassis
CacheVault Mount MCP-240-00127-0N 1 CacheVault mounting tray for 2.5" drive bay
MCP-240-21747-0N 1 CacheVault mounting card for AIOM slot
MCP-240-00203-0N 1 CacheVault mounting bracket for PCIe slot
GPU Power Cable CBL-PWEX-1361RF-10 1 12VHPWR 2x6+4S to ATX 2X4M P4.2 10cm
CBL-PWEX-1040 2 PWYCB GPU 2x4M/CPU to two (2x3F+2x1F)/PCIe P4.2 5CM
GPU Support (FL) SNK-P0087V 2 1U Passive CPU VC HS for X13 Intel Eagle Stream Platform
MCP-310-82621-0N 1 Plastic air shroud X13DDW for SCLA26-AW (GPU)
GPU Support (LP) MCP-310-82614-0B 1 Mylar air block set X12DDW for SCLA26-AW
License SFT-SDDC-SINGLE 1 Supermicro Data Center Monitor License
SFT-DCMS-SINGLE 1 Supermicro System Managment Software License
M.2 Tray AOC-SLG4-2H8M2 - Standard LP PCIe x8 supporting 2 PCIe 4.0 x4 M-Key M.2 NVMe/SATA Modules RAID 0, 1
NC-SI Cable CBL-PWEX-1099-34 1 FLAT IDC 2X11F/P1.27 TO IDC 2X11F/P1.27 NCSI 0.5A 35CM
NVMe Cable CBL-KIT-621C-TN12R-12 1 Enables 12 NVMe drive bays. Kit includes:
4x CBL-MCIO-1235M5FY (bay #2-5, #8-11)
2x CBL-MCIO-1255M5FH (bay # 0-1, #6-7)
Power Supply DC PWS-1K11P-1R 2 1010W Redundant DC Power Supply
Power Supply Upgrade PWS-1K68A-1R 2 1600W Redundant Titanium Level Power Supply
Rear NVMe Drive Kit CBL-MCIO-1235M5FY 1 MCIO x8 (STR) to 2x MCIO x4 (STR) 35CM
CBL-PWEX-1034Z-30 1 2 ATX 1x4 P4.2 to MicroHi 2x(4+2) 30cm 16AWG
MCP-220-82623-0N 1 Rear Window Module for 2x 2.5" NVMe Drives PCIE Gen 5
Rear SATA Drive Kit MCP-220-82616-0N 1 Rear Window Module for 2x 2.5" SATA/SAS Drives
SATA Cable CBL-KIT-SATA-CDC-1 1 Enables 12 SATA drive bays. Kit includes:
1x CBL-SAST-1274LP-100 (bay #0-7)
1x CBL-SAST-1285LP-100 (bay #8-11)
TPM AOM-TPM-9670V 1 SPI capable TPM 2.0 with Infineon 9670 controller vertical form factor
AOM-TPM-9670V-S-FIPS 1 SPI capable TPM 2.0 with Infineon 9670 controller w/ FIPS vertical form factor
AOM-TPM-9672V 1 SPI capable TPM 2.0 with Infineon 9672 controller vertical form factor
AOM-TPM-9672V-FIPS 1 SPI capable TPM 2.0 with Infineon 9672 controller w/ FIPS vertical form factor
VROC HW Key AOC-VROCPREMOD 1 Intel VROC Premium RAID 0, 1, 5, 10
AOC-VROCSTNMOD 1 Intel VROC Standard RAID 0, 1, 10

CloudDC SuperServer SYS-621C-TN12R (Complete System Only )

Certain products may not be available in your region